Diabetes testing
ADAMS A1c Lite HA-8380V
Smaller, but with full functionality
A compact HPLC HbA1c analyzer for smaller laboratories, with full functions and performance, cap-piercing sampling, results in IFCC and NGSP units, and easy, tool-free maintenance.

Overview
A compact HPLC HbA1c analyzer for smaller laboratories, with full functions and performance, cap-piercing sampling, results in IFCC and NGSP units, and easy, tool-free maintenance.
| Manufacturer | Arkray |
|---|---|
| Category | Diabetes testing |
| Installation & training | Included |
| Service coverage | Nationwide, certified engineers |
| Supplied in Iraq by | SAAEDA · official distributor |

For smaller laboratories
Smaller, but with full functionality: the ADAMS A1c Lite HA-8380V brings HPLC accuracy to laboratories with lower volumes, with full functions and performance in a compact size.
Two measurement modes
Specifications
| Measurement objects | Whole blood or hemolysis sample |
|---|---|
| Measured items | Fast Mode: HbA1c (Stable HbA1c, S-A1c) and HbF · Variant Mode: HbA1c (Stable HbA1c, S-A1c) and HbF (HbS and HbC separation and HbE and HbD detection can be performed). |
| Measurement principle | Reversed-phase cation exchange chromatography |
| Measurement wavelength | 420 nm/500 nm (Dual-wavelength colorimetry) |
| Resolution | 0.1% Ratio, 1 mmol/mol |
| Measurement range | HbA1c: 3 - 20%, 9 - 195 mmol/mol · HbF: 0 - 100% |
| Processing speed | Variant mode: 160 seconds/test · Fast mode: 100 seconds/test |
| Sample consumption | Whole blood sample: Approximately 4µL · Anemia sample: Approximately 8 µL · Hemolysis sample: Approximately 350 µL |
| Sample container | Sample tube: · (12.3 or 15 mm in outer diameter) × (75 to 100 mm in height) · Sample cup: 500 µL |
| Sample supply | Piercing sampling |
| Compatible rack type | ARKRAY racks (for 5 samples) |
| Operating environment | Temperature: 10 - 30°C; · Humidity: 20 - 80% RH (No condensation) |
| Display | 20 digits × 2 lines LCD |
| Printer | For use with 58-mm width thermal printer paper |
| Number of measurement samples | Maximum 10 samples |
| Power requirements | AC 100 - 240 V±10%, 50/60 Hz |
| Dimensions | 330 (W) × 515 (D) × 485 (H) mm · (Not including protrusions, eluent packs and hemolysis washing solution bottle) |
Manufacturer notes (1)