Skip to content
Molecular ImagingPET/CT

uMI Panvivo

An Advanced PET/CT to Empower Tomorrow for All

uMI Panvivo is a high performance PET/CT platform that moves state-of-the-art advancement to clinical reality. It advances diagnostic precision with NEMA spatial resolution of 2.9mm and time of flight (TOF) timing resolution of 219 picosecond (ps), while its air-cooled compact design makes it more accessible. The human-centric design and fully AI-empowered workflow of uMI Panvivo deliver care to every patient while keeping the user in mind.

24 cm AFOV
24 cm AFOV
30 cm AFOV
53 cm AFOV

Overview

uMI Panvivo is a high performance PET/CT platform that moves state-of-the-art advancement to clinical reality. It advances diagnostic precision with NEMA spatial resolution of 2.9mm and time of flight (TOF) timing resolution of 219 picosecond (ps), while its air-cooled compact design makes it more accessible. The human-centric design and fully AI-empowered workflow of uMI Panvivo deliver care to every patient while keeping the user in mind.

ManufacturerUnited Imaging
CategoryMolecular Imaging
Installation & trainingIncluded
Service coverageNationwide, certified engineers
Supplied in Iraq bySAAEDA · official distributor
01Precision for All
02Care for All
03Success for All

uMI Panvivo Family: A Scalable Platform

Lymphoma, Initial Staging BMI 30High-Resolution PET/CT for Clear Delineation of Lymphoma HeterogeneityLymphoma, Initial Staging BMI 30PET Imaging Protocol 18F-FDG 4.5 mCi (165 MBq, 1.8 MBq/kg) Uptake time: 79 minutes Total scan time: 8 minutes uMI Panvivo M Images courtesy of the First People's Hospital of Kunshan, JS, CHN 2.9mm NEMA Spatial Resoluti…Images courtesy of the First People's Hospital of Kunshan, JS, CHN 2.
Lymphoma 73/F 58 kg 143 cm BMI 285 min Fast Whole-body Imaging with Clear Delineation of Small LesionsLymphoma 73/F 58 kg 143 cm BMI 28PET Imaging Protocol 18F-FDG 3.9 mCi (145 MBq, 2.5 MBq/kg) 126-min p.i. delay scan Total scan time: 5 min uMI Panvivo S Images courtesy of the First People's Hospital of Kunshan, JS, CHN 5 min Fast Whole-body Imaging w…Images courtesy of the First People's Hospital of Kunshan, JS, CHN 5 min Fast Whole-body Imaging with Clear Delineation of Small Lesions 2.
Multiple Myeloma BMI 27.9High Resolution PET/CT Imaging Enables Detecting Small LesionsMultiple Myeloma BMI 27.9Imaging Protocol 18F-FDG 5.5 mCi (203 MBq, 2.1 MBq/kg) Uptake time: 72 minutes Total scan time: 6 minutes uMI Panvivo Images courtesy of Pueblo Medical Imaging, NV, USA High Resolution PET/CT Imaging Enables Detecting …Images courtesy of Pueblo Medical Imaging, NV, USA High Resolution PET/CT Imaging Enables Detecting Small Lesions Half Dose Fast Total-body Imaging for a High BMI Patient Cancer Restaging BMI 53 Imaging protocol 18F-FDG 5.
Breast Ca Restaging BMI 25Clear Delineation of Lesions from Vertex to Toe in 4 minBreast Ca Restaging BMI 25Imaging Protocol 18F-FDG 2.6 mCi (90 MBq, 1.5 MBq/kg) Uptake time: 84 minutes Total scan time: 4 minutes uMI Panvivo ES Images courtesy of the First People's Hospital of Kunshan, JS, CHN Clear Delineation of Lesions fr…Images courtesy of the First People's Hospital of Kunshan, JS, CHN Clear Delineation of Lesions from Vertex to Toe in 4 min Improving Small Lesion Detectability and Delineation with 219 ps TOF Resolution Prostate Cancer BMI 24 Imaging Protocol 18F-PSMA 3.
AFOV off-center, vertex 8 cm away from edge8 min 1024 × 1024 High Resolution Brain Imaging positioned at edge of AFOVAFOV off-center, vertex 8 cm away from edge18F-FDG 5.9 mCi (218 MBq) Uptake time: 40 minutes Total scan time: 8 minutes uMI Panvivo EX Images courtesy of the First People's Hospital of Kunshan, JS, CHN High Resolution Brain Imaging positioned at edge of AFOV 3 …Images courtesy of the First People's Hospital of Kunshan, JS, CHN High Resolution Brain Imaging positioned at edge of AFOV 3 min Fast Scan with Low Dose Usage T-cell lymphoma BMI 22 Imaging Protocol 18F-FDG 2.
Age/Gender: 70-year-old, male Ht 169 cm (5'7'') BMI 25Dual Tracer Imaging of Multiple Myeloma with History of Prostate CancerAge/Gender: 70-year-old, male Ht 169 cm (5'7'') BMI 25Imaging Protocol 18F-FDG 2.8mCi (105 MBq,1.5 MBq/kg) Uptake time: 59 min 18F-PSMA 3.1 mCi (115 MBq,1.6 MBq/kg) Uptake time: 121 min Acquisition time: 3 min vertex to toe Recon Parameters Matrix 600 × 600 Voxel 1.2 × 1.…Images courtesy of the First People's Hospital of Kunshan, JS, CHN Dual-Tracer Scan of Patient with Multiple Myeloma Dynamic Imaging of Multiple Myeloma with History of Prostate Cancer BMI 25 Imaging Protocol 18F-PSMA Total: 3.
Precision for All

Precision for All

Driven by precision medicine and personalized care, uMI Panvivo Family offers the top-tier performance based on state-of-the-art detector technology and highly integrated system for better diagnostic confidence and capabilities.

Top-tier Performance

2.9 mmExceptional NEMA spatial resolution delivered by the finest crystal size of 2.76 mm in the industry.
219 psLeading TOF resolution that boosts small lesion detectability and clarity.
Scalable PlatformOn-site upgradable for enhanced imaging capability and more clinical possibilities.
High Effective SensitivityBenefits from TOF gain leverages better diagnostic accuracy under low dose usage and fast scan time.

Clarity Enhanced by TOF resolution

High-definition (HD) Resolution up to 1.6mmHigh-definition (HD) Resolution up to 1.6mmHigh-definition (HD) Resolution up to 1.6mmMini-deluxe Phantom HD Resolution 1.6 mm 1.17 mCi, 20 min TOF-PSF-OSEM 50i20s 0.6 × 0.6 × 0.8 mm³ no smoothing uMI Panvivo
High Resolution Image of 18F-FDG Brain PET/CT ScanHigh Resolution Image of 18F-FDG Brain PET/CT ScanHigh Resolution Image of 18F-FDG Brain PET/CT ScanImaging Protocol 18F-FDG 7.03 mCi (260 MBq) Uptake time: 83 minutes uMI PanvivoImages courtesy of the First People's Hospital of Kunshan, JS, CHN
4 min Fast Total-body Imaging4 min Fast Total-body Imaging4 min Fast Total-body ImagingLung Cancer, Restaging BMI 21 Imaging Protocol 18F-FDG 6.54 mCi (242 MBq) Uptake time: 54 minutes uMI PanvivoImages courtesy of the First People's Hospital of Kunshan, JS, CHN
Low Dose Imaging of Large PatientLow Dose Imaging of Large PatientLow Dose Imaging of Large PatientBilateral Breast Cancer, Initial Staging BMI 36 Imaging Protocol 5.7 mCi (211 MBq) Uptake time: 69 minutes Total scan time: 8 minutes uMI PanvivoImages courtesy of Pueblo Medical Imaging, NV, USA
Exceptional TOF Resolution Unveils Hidden Lesions with Clear Delineation and Quantitative AccuracyExceptional TOF Resolution Unveils Hidden Lesions with Clear Delineation and Quantitative AccuracyExceptional TOF Resolution Unveils Hidden Lesions with Clear Delineation and Quantitative AccuracyBreast Cancer BMI 25 Imaging Protocol 18F-FDG 11.7 mCi (432 MBq) Uptake time: 65 minutes Total scan time: 8 minutes uMI PanvivoImages courtesy of Pueblo Medical Imaging, NV, USA
Clear Visualization of Lesion in 68Ga-PSMA ImagingClear Visualization of Lesion in 68Ga-PSMA ImagingClear Visualization of Lesion in 68Ga-PSMA ImagingLocally Advanced Prostate Cancer BMI 28 Imaging Protocol 68Ga-PSMA 3.8 mCi (141 MBq) Uptake time: 69 minutes Total scan time: 8 minutes uMI PanvivoImages courtesy of Pueblo Medical Imaging, NV, USA
Care for All

Care for All

uMI Panvivo Family represents the very idea of care for all through incorporating patient-centric design and embracing power of Artificial Intelligence to enhance patient and user experience, and overall efficiency.

AI-Powered Post-Processing Solution with uOmnispace

Driving intelligent insights, precision evaluation in oncology and personalized theranostics with auto segmentation, reading and reporting

Comprehensive cardiac quantification package for cardiac perfusion, function, and viability

Comprehensive brain quantification tools for neurodegenerative disease

Easy access, scalable, and multi-vendor

Scalable modality or departmental, enterprise solution that adapts to your clinical and IT needs.

Enjoyable Scan Experience with Human-centric Design

Bigger tunnel clearance

uMI Panvivo provides maximum tunnel clearance up to 59cm at the lowest table height, creating spacious room for larger patients and various accessories or postures.

Soothing Ambient Lighting

Purple, blue and white ambient lighting with breathing guide helps reduce patient anxiety and claustrophobia.

Convenient Operation at Bedside

Using Control Panel (CPAN) to start the PET scan at bedside allows one person to administer radiotracer and start the acquisition afterwards in scan room, particularly for Myocardial Perfusion Imaging (MPI) or Dynamic Imaging.

Seamless Total-Body Scan

uMI Panvivo offers a 2-meter uninterrupted scan range for total-body imaging in a single exam-without repositioning or image stitching. The streamlined process delivers faster exams, greater patient comfort, and improved efficiency.

Success for All

Success for All

uMI Panvivo Family aims to accompany you on the journey towards long-term and sustainable success.

Expanding Clinical Versatility

High NECR performance supports precision imaging in various clinical fields

The integrated features that extend clinical use beyond imaging and diagnosis

Build Tomorrow with Adaptive Design

Improved Accessibility Delivered by A Compact Structure

Long-term Success with Consistency in Performance

uMI Panvivo Family

uMI Panvivo Family

uMI Panvivo is a powerful platform that enables diagnostic confidence, operational excellence with exceptional imaging capability, AI-powered workflow and compact and scalable design.

0.3 s Rotation Speed

Reduce total acquisition and breath hold times.

100 kW Generator

Provide high power output and reliable performance.

280 kg Weight Capacity with Anti-collision Mechanism

To ensure a safer procedure, the column will stop automatically once an object or foot being detected under the base.

0.5 mm × 80 rows with 3D collimator grid up to 160 slices/rotation.

AI-assisted Patient Positioning

uExcel uVision, an AI-powered workflow that delivers the patient to the isocenter automatically and accurately based on the targeted region identified by the 3D camera in accordance with protocol.

Air-cooled System

Offer great performance stability without water chiller therefore no equipment room needed.

Extra Big Tunnel Clearance of 59 cm (23.2 in)

Create spacious room for larger patients and various accessories or postures.

Leading Performance with Extendable PET AFOV

2.9 mm

NEMA Spatial Resolution

219 ps

TOF Resolution

Extendable PET AFOV

Max. 2 m (78.7 in) Co-Scan Range

Allow efficient and comprehensive coverage for total-body imaging.

Manufacturer notes (4)
  1. 4 cm CT Detector Coverage
  2. 24 cm, 30 cm, 53 cm, 71 cm, 107 cm…
  3. DISCLAIMERS
  4. 1. Currently, the scalability can only be applied to specific models in uMI Panvivo Family. It may not be commercially available in all countries. Please check with your local United Imaging Healthcare representative for availability. 2. Data calculated with 35-cm object size. 3. Aforementioned Image quality improvement and compatibility of different radiopharmaceuticals apply to uMI Panvivo and uMI Panvivo S. Currently uExcel DPR 2.0 on uMI Panvivo ES / EX / LS only supports FDG for clinical use. 4. uOmnispace can be deployed in conjunction with UII's PET-CT Oncology, which is not part of this product. Please visit uii-ai.com for more information on compliance, safety, and effectiveness of this application. 5. Earl: EANM Research Ltd. 6. uOmnispace is an independently registered product that is FDA 510(k) and CE MDR cleared. The product may not be commercially available in all countries. Please check with your local United Imaging Healthcare representative for availability. This product is intended for use by trained medical professionals only. Patients should follow the guidance and instructions provided by healthcare practitioners during operation. United Imaging does not make any claims regarding the safety and effectiveness of tracers that have not been approved by the FDA or CE. Onscreen reproduction and display may result in a certain degree of image-quality degradation. Please contact your local United Imaging Healthcare organization for further details.
Specifications

Technical data

NEMA spatial resolution2.9 mm
TOF resolution219 ps
Crystal size2.76 mm
PET axial FOV (uMI Panvivo)30 cm
Extendable PET AFOV (uMI Panvivo Family)24 cm, 30 cm, 53 cm, 71 cm, 107 cm…
Effective sensitivity (uMI Panvivo, 35-cm object size)181 cps/kBq
CT detector coverage4 cm (0.5 mm × 80 rows, up to 160 slices/rotation)
Rotation speed0.3 s
Generator100 kW
Weight capacity280 kg
Tunnel clearance59 cm (23.2 in)
Co-scan rangeMax. 2 m (78.7 in)
CoolingAir-cooled system (no equipment room needed)
HD resolution (phantom)up to 1.6mm
Molecular Imaging

Related devices

View the whole category
Molecular ImagingUnited Imaging uMI Panorama GS
United ImagingMolecular Imaging

uMI Panorama GS PET/CT

Next-Generation 148-cm Whole-Body PET/CT

uMI Panorama GS is an advanced PET/CT solution for whole-body imaging, featuring state-of-the-art uExcel technology. It is the first whole-body system to break the 200 ps timing barrier and boasts an impressive 148 cm axial field of view (FOV). It is equipped with the next-generation Ultra Digital Platform (UDP) detector, uExcel UDP, which enables record-breaking time-of-flight (TOF) performance, exceptional spatial resolution, and remarkable system sensitivity.

View details
Molecular ImagingUnited Imaging uEXPLORER
United ImagingMolecular Imaging

uEXPLORER Total-body PET/CT

The World's First Total-Body PET/CT

The uEXPLORER is an ultra-high-resolution digital PET/CT with a 194cm axial PET field of view (FOV) that enables the entire body to be scanned in one bed position. The system offers total-body dynamic scanning, which enables ultra-low patient doses and produces ultra-high image resolution. With total-body coverage and unprecedented sensitivity, uEXPLORER is able to capture dynamic changes to radiotracer distribution with ultra-high temporal resolution.

View details
Molecular ImagingUnited Imaging uPMR 790
United ImagingMolecular Imaging

uPMR 790 PET/MR

HD TOF PET/MR

The uPMR 790 enables simultaneous PET/MRI imaging with high temporal and spatial resolution. Next generation PET and MRI technologies redefine routine clinical imaging of real-time anatomical and functional imaging, while redefining cutting edge research imaging.

View details
Molecular ImagingUnited Imaging uMI Panorama
United ImagingMolecular Imaging

uMI Panorama PET/CT

New-Generation Ultra-High Resolution Digital PET/CT

uMI Panorama is an ultra-high resolution digital PET/CT powered by the uExcel technology platform. It offers the finest NEMA PET spatial resolution, truly-fast 189-picosecond (ps) time of flight (TOF), scalable axial field of view (AFOV), the 76-cm super-wide bore and 318-kg table weight capacity that accommodates patients of all sizes. By leveraging the AI-powered features on the uExcel platform, it also boosts daily work efficiency significantly and opens up new possibilities for exploration.

View details
Molecular ImagingUnited Imaging uMI 780
United ImagingMolecular Imaging

uMI 780 PET/CT

Ultra-Fast High Resolution Digital PET/CT

Combining a long axial FOV digital PET with a 160-slice CT, the powerful uMI 780 scanner provides 2.9mm NEMA resolution, 16cps/kBq sensitivity and a 30cm axial FOV for a revolutionary breakthrough in the combination of clarity, sensitivity, coverage and speed. It features a 112-ring PET with Integrated-Light-Guide Digital Detector and a 160-slice CT with innovative Z-detector.

View details
Molecular ImagingUnited Imaging uMI Vista
United ImagingMolecular Imaging

uMI Vista PET/CT

High-Resolution Digital PET/CT

With the unique Integrated-Light-Guide Digital PET technology and a 160-slice CT system, uMI Vista combines high quality functional images with fine anatomical structure visualization. The state-of-the-art reconstruction technology and comprehensive applications further boost diagnostic precision in oncology, neurology and cardiology.

View details
Talk to an expert

Your trusted partner in healthcare.

Tell us what you need. A specialist will call you back within one business day.