uCT 820

Intelligence That Adapts. Clarity That Transcends.

The uCT 820 scanner is equipped with advanced AI technologies and designed with a patient-centered philosophy. It provides comprehensive tissue characterization, minimizes radiation exposure, enables rapid volumetric imaging, and streamlines exam setup for enhanced patient throughput. uCT 820 delivers an exceptional premium CT examination experience for both you and your patients.

Overview

The uCT 820 scanner is equipped with advanced AI technologies and designed with a patient-centered philosophy. It provides comprehensive tissue characterization, minimizes radiation exposure, enables rapid volumetric imaging, and streamlines exam setup for enhanced patient throughput. uCT 820 delivers an exceptional premium CT examination experience for both you and your patients.

ManufacturerUnited Imaging
CategoryComputed Tomography
ClassPremium CT
Installation & trainingIncluded
Service coverageNationwide, certified engineers
Supplied in Iraq bySAAEDA · official distributor

Intelligence That Adapts. Clarity That Transcends.

uCT 820 scanner is equipped with advanced AI technologies and designed with a patient-centered philosophy. It provides comprehensive tissue characterization, minimizes radiation exposure, enables rapid volumetric imaging, and streamlines exam setup for enhanced patient throughput. uCT 820 delivers an exceptional premium CT examination experience for both you and your patients.

Premium Clinical Versatility

Premium Clinical Versatility

With an AI-empowered workflow that covers the entire process from scanning to diagnosis, the uCT 820 scanner provides an excellent CT examination experience that is both highly intelligent and precise. You can now deal with challenging clinical scenarios with ease.

PositioninguAI Vision provides streamlined, standardized isocentric positioning for each exam.
ScanningTailored imaging for each individual through the intelligent scanning planning.
ReconstructionBy employing a range of intelligent reconstruction algorithms, the quality of clinical images can be significantly enhanced.
Post Processing**Streamlined post-processing applications for superior quality of CT imaging and high efficiency of diagnosis.
AIIR* - AI Iterative Reconstruction

AIIR* - AI Iterative Reconstruction

As the world's first** combined AI and IR–based reconstruction, AIIR is a pioneering image reconstruction approach that integrates a holistic model-based iterative reconstruction (MBIR) with advanced deep learning technology.

0.5 mm Pixels

0.5 mm Pixels

With a 0.5 mm detector pixel size, finer structures can now be better visualized with every scan. The improvement of Z-axis resolution also helps to reduce partial volume effects and improve the ability to identify overlapping lesions.

1024 x 1024 Reconstruction Matrix

1024 x 1024 Reconstruction Matrix

A 1024 x 1024 Reconstruction Matrix enhances the spatial resolution and helps reveal the smallest of details for the most challenging examinations.

CardioBoost

CardioBoost

AI-based reconstruction algorithm specialized in cardiac imaging, providing exceptional spatial resolution and artifact suppression capability.

CardioXphase

CardioXphase

AI-driven optimal phase selection, which enables high-quality coronary CTA imaging while reducing technologists' efforts for image processing and reconstruction.

0.25 s Rotation Speed

0.25 s Rotation Speed

The system features a one-piece casted gantry structure integrated with a direct motor system that provides precise rotation speed control, enabling a 0.25 s rotation speed and exceptional temporal resolution.

CardioCapture

CardioCapture

Using an intelligent motion correction with an AI-empowered coronary artery algorithm, we have improved the temporal resolution for cardiac imaging to 25 milliseconds.

Motion Freeze

Motion Freeze

AI-based head motion correction algorithm, revealing the truth underneath the motion artifacts.

180 mm Dynamic Cerebral Perfusion

180 mm Dynamic Cerebral Perfusion

The dynamic perfusion technique provides a wider perfusion scanning range than the detector coverage and delivers full brain functional information with up to 2 seconds cycle time.

Automated Post-processing*

Automated Post-processing*

With the use of automatic bone removal, CTA images can be obtained quickly and accurately. Moreover, the CTP analysis software offers a range of functional parameters, including CBV, CBF, TTP, MTT, and Tmax, to enhance the precision of diagnosis for ischemic stroke.

Equivalent 34 MHU Heat Capacity

Equivalent 34 MHU Heat Capacity

Advanced liquid-metal bearing technology enables the scanner to be prepared for any type of scan at any time.

Real Time 3D

Real Time 3D

Real-time image preview enables quicker identification of lesions, making it particularly suitable for emergency departments.

Automated Post-processing

Automated Post-processing

The automatic marking of ribs and vertebral discs facilitates prompt diagnosis of bone factures.

Premium Patient Care

With the full-chain low dose technology and patient-friendly design, uCT 820 brings unparalleled patient experience, allowing radiologists and technologists to focus more on the patients rather than the procedures.

Ultra EFOV

Ultra EFOV

AI-empowered algorithm that enables entire bore size imaging and truncation artifacts suppression.

82 cm Ultra-wide Bore

82 cm Ultra-wide Bore

The spacious 82 cm bore enables a comfortable patient examination experience and a flexible operating space, while also providing enhanced imaging capabilities for bariatric patients.

60 kVp Scan Mode

60 kVp Scan Mode

Organ based Auto ALARA mA

Organ based Auto ALARA mA

Automatic recognition of the chest and abdomen with an AI-based technology allowing optimized dose planning and image quality for the entire scan range.

uAI Vision

uAI Vision

The auto ISO centering function optimizes the radiation dose and image quality without regard to the operator's skill variance.

Z-Detector

Z-Detector

Based on through-silicon via (TSV) technology, the Z-Detector results in almost loss-free digitized signals, significantly reducing the overall image noise and reducing radiation dose.

Built Upon a Powerful Foundation

With a robust imaging chain that includes Z-Detector technology, a rotation speed of 0.25 s, a Equivalent 34 MHU heat capacity, and an ultra-wide 82 cm bore, alongside a table weight capacity of 318 kg, and advanced clinical solutions to facilitate imaging of a diverse range of patients and exam types, including advanced cardiac, acute care, and trauma cases.

Enhanced Visualization with Stents

CardioBoost significantly reduces image noise, providing clearer visualization of coronary arteries and enhanced contrast within stented vessels. It delivers sharper and more defined stent contours, enabling a more intuitive analysis of post-stent implantation outcomes.

Enhanced Visualization with Stents

Enhanced Visualization with Stents

CardioBoost significantly reduces image noise, providing clearer visualization of coronary arteries and enhanced contrast within stented vessels. It delivers sharper and more defined stent contours, enabling a more intuitive analysis of post-stent implantation outcomes.

CorCTA Helical

kV: 100 mAs: 160 CTDIvol: 27.451 mGy ED: 7.17 mSv

Reconstruction

Matrix: 512 x 512 0.75 mm x 0.5 mm WW/WL: 1200/400 HIR: C_SOFT_BA, KARL: 5 CardioBoost: 3

Contrast

Clear Delineation of Plaque Contours

Clear Delineation of Plaque Contours

CardioBoost can provide clearer visualization of coronary arteries. It enhances the delineation of plaque contours, with sharper differentiation between hard plaques and soft plaques.

CorCTA Helical

kV: 100 mAs: 140 CTDIvol: 29.29 mGy ED: 6.34 mSv

Reconstruction

Matrix: 512 x 512 0.75 mm x 0.5 mm WW/WL: 1000/200 HIR: C_SOFT_BA. KARL: 5 CardioBoost: 3

Contrast

Improved Visualization for Enhanced Confidence

Improved Visualization for Enhanced Confidence

CardioBoost significantly reduces image noise, providing clearer visualization of coronary arteries. For bypass patients, it enables more accurate extraction of graft vessels and improved visualization of distal vessels, assisting clinicians in better assessing patient prognosis.

CorCTA Helical

kV: 100 mAs: 160 CTDIvol: 32.151 mGy ED: 7.13 mSv

Reconstruction

Matrix: 512 x 512 0.75 mm x 0.5 mm WW/WL: 1000/200 HIR: C_SOFT_BA, KARL: 5 CardioBoost: 3

Contrast

Optimal phase selection for coronary

Optimal phase selection for coronary

CardioXphase can intelligently identify the optimal phase for coronary imaging, resulting in significantly improved image quality compared to the default 45% and 75% phases.

CorCTA Helical

kV: 100 CTDIvol: 26.00 mGy

Reconstruction

Matrix: 512 x 512 0.75 mm x 0.5 mm WW/WL: 700/100 HIR: C_SOFT_BA, KARL: 5 CardioXphase: 39%

Contrast

Coronary Motion Suppression

Coronary Motion Suppression

CardioCapture reduces coronary blurring artifacts caused by cardiac motion technology, providing superior diagnostic image quality for patients with high heart rates.

CorCTA Helical

kV: 100 CTDIvol : 37.96 mGy

Reconstruction

Matrix: 512 x 512 0.5 mm x 0.5 mm WW/WL: 700/100 HIR: C_SOFT_BA, KARL: 8 CardioXphase: 42% CardioCapture Level: 5

Contrast

Clear Depiction with Arrhythmia

Clear Depiction with Arrhythmia

uCT 820 allows cardiac scanning at an irregular heart rate ranging from 51 to 89 bpm. Calcified plaques with mild lumen stenosis are clearly depicted in the middle segment of the left anterior descending artery.

CorCTA Helical

kV: 100 CTDIvol: 29.29 mGy

Reconstruction

Matrix: 512 x 512 0.75 x 0.5 mm WW/WL: 1000/200 HIR: C_SOFT_BA, KARL: 5 CardioXphase: 78% CardioCapture Level: 7

Contrast

Heart Rate

Avg HR: 58 bpm Min HR: 51 bpm Max HR: 89 bpm

Triple-rule-out

Triple-rule-out

uCT 820 supports triple-rule-out imaging, enabling the comprehensive evaluation of coronary arteries, the aorta, pulmonary arteries, and pulmonary veins in a single scan with exceptional clarity.

Triple-rule-out

kV: 100 CTDIvol: 25.65 mGy

Reconstruction

Matrix: 512 x 512 0.5 x 0.5 mm WW/WL: 1000/200 HIR: C_SOFT_BA, KARL: 8 CardioXphase: 60% CardioCapture Level: 5

Contrast

Aorta CTA with AIIR

Aorta CTA with AIIR

AIIR can reduce image noise, enhances vascular visualization. By enriching fine details, AIIR significantly increases the detectability of small lesions.

Aorta CTA Helical

kV: 120 kV, mAs: 100 CTDIvol: 5.504 mGy ED: 7.09 mSv

Reconstruction

Matrix: 512 x 512 1.0 x 0.5 mm HIR: B_SOFT_B, KARL: 5 AIIR: 3

Contrast

65ml, 5.0ml/s

AIIR for Better Artifact Suppression

AIIR for Better Artifact Suppression

AIIR reduces image noise and significantly suppresses beam hardening artifacts in acromioclavicular and hip joints, enhancing diagnostic confidence.

Chest Union Abdomen Helical

kV: 120 kV, mAs: 64 mAs CTDIvol: 4.851mGy ED: 6.13 mSv

Reconstruction

Matrix: 512 x 512 1.0 x 0.5 mm HIR: B_SOFT_B AIIR: 3 WW/WL: 350/40

Contrast

-

AIIR with 60 kV Low Dose Lung Screening

AIIR with 60 kV Low Dose Lung Screening

AIIR enhances the clarity of fissure visualization and improves the distinction between lung segments. The refined clarity facilitates lesion detection and localization, enhancing the diagnostic confidence, and meanwhile, maintaining the low radiation dose.

Chest Helical

kV: 60 kV, mAs: 360 CTDIvol: 2.382mGy ED: 0.98 mSv

Reconstruction

Matrix: 512 x 512 1.0 x 0.5 mm AIIR: 3 WW/WL: 1100/-600

Contrast

-

Carotid CTA with Automated Bone Removal

Carotid CTA with Automated Bone Removal

uCT 820 precisely removes bone structures without residual artifacts, ensuring continuous visualization of intracranial and vertebral arteries with enhanced detail in peripheral vessels.

CorCTA Helical

kV: 120 mAs: 186 CTDIvol: 14.03 mGy ED: 1.86 mSv

Reconstruction

Matrix: 512 x 512 1.5 x 1.0 mm HIR: H_SOFT_B, KARL: 5

Contrast

Kidney Rupture in Emergency

Kidney Rupture in Emergency

uCT 820 enables rapid 670 mm whole-abdomen scanning, facilitating the diagnosis of right kidney atrophy and left kidney rupture.

Abdomen Helical

kV: 120 mAs: 173 CTDIvol: 13.04 mGy ED: 9.87 mSv

Reconstruction

Matrix: 512 x 512 3.0 x 3.0 mm HIR: H_SOFT_B, KARL: 5

Contrast

Dual Energy Imaging

Dual Energy Imaging

The uCT 820 is equipped with dual-energy imaging, which supports the use of base material maps, pseudo-color maps, histograms, volume statistics for analysis, and visualization of small stones (about 4 mm in diameter) through VR images. The histogram demonstrated that the stones are mainly composed of magnesium ammonium phosphate and cysteine.

Abdomen Helical DE

kV: 140 mAs: 180 CTDIvol: 19.706 mGy

Reconstruction

Matrix: 512 x 512 1.0 x 1.0 mm HIR: B_SOFT_B, KARL: 5

Contrast

-

Bariatric Imaging with Ease

Bariatric Imaging with Ease

uCT 820 is designed to scan obese patients with a BMI over 35, delivering high-quality images. Its 82 cm wide aperture ensures a comfortable scanning experience for patients with body sizes exceeding 500 mm.

Abdomen Helical

kV: 120 mAs: 272 CTDIvol: 20.628 mGy

Reconstruction

Matrix: 512 x 512 Non-contrast: 1.0 x 1.0 mm HIR: B_SHARP_C, KARL: 5 Arterial Phase: 5.0 x 5.0 mm HIR: B_SOFT_B: KARL: 5 Venous Phase: 5.0 x 5.0 mm HIR: B_SOFT_B, KARL: 5

Contrast

100 ml, 3.5 ml/s

Technical Specifications

Gantry bore size82 cm
Gantry tilt±30°
Tube heat capacityEquivalent 34 MHU
Number of slicesUp to 160 slices/rotation
Rotation timeUp to 0.25 sec/rotation
Temporal resolutionUp to 25 ms with CardioCapture
Table loadUp to 318 kg*
kV settings60/70/80/100/120/140 kV

* Optional

Manufacturer notes (11)
  1. 60 ml, 5.0 ml/s
  2. 65 ml, 5.0 ml/s
  3. 65 ml, 5.5 ml/s
  4. 60 ml, 5 ml/s
  5. 80 ml, 5 ml/s
  6. 60 ml, 4 ml/s
  7. 80 ml, 3 ml/s
  8. The product may not be commercially available in all countries. Please check with your local United Imaging Healthcare representative for availability.
  9. This product is intended for use by trained medical professionals only. Patients should follow the guidance and instructions provided by healthcare practitioners during operation.
  10. The supported languages of instruction for use include: English, Russian, Spanish and Italian, Polish, German, Greek, Romanian, Hungarian, and Brazilian Portuguese, et al. Qualified users may access the instruction for use in the appropriate language via the provided link: https://uicloud.com/uclass/docs/en-us/home
  11. Please contact your local United Imaging Healthcare organization for further details.
Computed Tomography

Related devices

View the whole category
Dual-wide Coverage CTUnited Imaging uCT SiriuX Ultrix
United ImagingComputed Tomography

uCT SiriuX Ultrix CT

Profound Acuity. Translating Vitality.

uCT SiriuX Ultrix brings a new level of versatility to CT imaging. Its dual-wide coverage architecture integrates high spatial resolution, fast temporal resolution, extensive volumetric coverage, low-dose imaging, and high-definition spectral imaging within a single platform. From anatomical detail to physiological motion and material composition, it offers a broader view of what CT can reveal.

View details
Dual-wide Coverage CTUnited Imaging uCT SiriuX
United ImagingComputed Tomography

uCT SiriuX CT

Vertices Unite, Innovations Ignite

CT continues to evolve, moving beyond static anatomy to reveal the dynamics of human physiology. With its dual-wide coverage architecture, uCT SiriuX combines ultra-fast temporal resolution, extensive volumetric coverage, and advanced spectral imaging. It enables clinicians to see more, understand more, and capture the dynamics of life.

View details
Premium CTUnited Imaging uCT 960+
United ImagingComputed Tomography

uCT 960+ CT

Attainable Intelligence. Simply Masterful.

Born with AI, uCT 960+ is an ultra-premium CT scanner equipped with industry-leading AI-empowered technologies. Its AI features give it the capability to deliver unmatched image quality for confident diagnoses with exceptional clinical efficacy. By infusing AI with an elevated hardware platform, uCT 960+ offers precise imaging and ease of use for all types of patients from routine to advanced applications, including cardiac, acute care, trauma, and oncology.

View details
Premium CTUnited Imaging uCT 868
United ImagingComputed Tomography

uCT 868 CT

From Intelligence to Instinct

The uCT 868 ushers in a new era of high-end CT imaging, seamlessly integrating advanced AI with hardware excellence. By uniting advancements in image perception, motion detection, and workflow optimization, this platform empowers healthcare professionals to see more, achieve more, and operate less.

View details
Performance CTUnited Imaging uCT 780
United ImagingComputed Tomography

uCT 780 CT

Precision. Accelerated.

As clinical examinations become more complex, the demands on CT scanner performance increase, requiring improvements not only in patient care but also in workflow efficiency. uCT 780, equipped with advanced AI technology, enhances image quality while reducing dose, simplifies the examination process for technicians, and offers versatility for radiologists handling a broad spectrum of clinical scenarios.

View details
Performance CTUnited Imaging uCT 760
United ImagingComputed Tomography

uCT 760 CT

Performance. Profound.

The uCT 760 is a 128-slice CT featuring a fully integrated Z-Detector. The ultra-low electronic noise of the Z-Detector, along with a powerful imaging chain, greatly improves the clinical user experience. The system reveals diagnostic details with minimized radiation dose and provides comprehensive and reliable cardiac imaging capability.

View details
Talk to an expert

Your trusted partner in healthcare.

Tell us what you need. A specialist will call you back within one business day.