Skip to content
Computed TomographyPremium CT

uCT 960+

Attainable Intelligence. Simply Masterful.

Born with AI, uCT 960+ is an ultra-premium CT scanner equipped with industry-leading AI-empowered technologies. Its AI features give it the capability to deliver unmatched image quality for confident diagnoses with exceptional clinical efficacy. By infusing AI with an elevated hardware platform, uCT 960+ offers precise imaging and ease of use for all types of patients from routine to advanced applications, including cardiac, acute care, trauma, and oncology.

Up to 99%*
Up to 70%*
Up to 72%*
Up to 267%*

Overview

Born with AI, uCT 960+ is an ultra-premium CT scanner equipped with industry-leading AI-empowered technologies. Its AI features give it the capability to deliver unmatched image quality for confident diagnoses with exceptional clinical efficacy. By infusing AI with an elevated hardware platform, uCT 960+ offers precise imaging and ease of use for all types of patients from routine to advanced applications, including cardiac, acute care, trauma, and oncology.

ManufacturerUnited Imaging
CategoryComputed Tomography
ClassPremium CT
Installation & trainingIncluded
Service coverageNationwide, certified engineers
Supplied in Iraq bySAAEDA · official distributor
Experiencing unrestricted cardiac imaging.True Cardiac Vision
Improving your clinical applications and efficiency through innovative AI technologies.AI-driven Smart Imaging
Expanding clinical offerings, leaving no patients behind.All-rounded Clinical Versatility

True Cardiac Vision

Cardiovascular diseases are the most common cause of death globally and Coronary CT Angiography (CCTA) is the examination method that is highly recommended by European Society of Cardiology (ESC), American Heart Association (AHA), and many other institutions. However, since the heart is constantly beating during the examination, cardiac imaging is one of the most challenging scenarios. uCT 960+ equipped with unparallel AI features has now made it simple as breathing. Paired with elevated hardware, 16 cm Z-axis coverage detector and 0.25 sec rotation speed, uCT 960+ can provide seamless examination experience and meanwhile, eliminates the restriction of patients, allowing high heart rate, arrhythmia, and free breathing cardiac imaging.

CardioBoost

AI-empowered cardiac imaging reconstruction.

Contrast Boost

Resolution Boost

Resolution Boost

Spatial Attention Module

Bringing clearer visualization of the targeting area such as plaques and stents.

Up to 72%*

Improvements in spatial resolution with the same radiation dose

Artifacts Suppression

Artifacts Suppression

With spatial attention module, it can reduce blooming artifacts, and therefore allowing a precise evaluation about the degrees of coronary stenosis.

Up to 99%*LCD enhancement with the same dose level
Up to 70%*Dose reduction with the same LCD level
Up to 72%*Improvements in spatial resolution with the same radiation dose

Improved Depiction of Non-calcified Plaques

CardioBoost delivers higher resolution of distal vessels and, meanwhile, provides clearer depiction with lower noise of the non-calcified plaques.

Improved Depiction of Non-calcified Plaques

Improved Depiction of Non-calcified Plaques

CardioBoost delivers higher resolution of distal vessels and, meanwhile, provides clearer depiction with lower noise of the non-calcified plaques.

CorCTA Axial

kV: 100 mAs: 187 0.25 s/rotation CTDIvol: 21.13 mGy ED: 4.73 mSv

Reconstruction

Matrix: 512 x 512 Slice: 0.50 x 0.50 mm WW/WL: 800/150 HIR: C_SOFT_AA, KARL: 8 CardioBoost: 1

Contrast

Uncompromised by Stents

Uncompromised by Stents

CardioBoost can reduce image noise and, meanwhile, improve the stent resolution with clear contours.

CorCTA Axial

kV: 120 mAs: 148 0.25 s/rotation CTDIvol: 26.827 mGy ED: 5.26 mSv

Reconstruction

Matrix: 512 x 512 Slice: 0.50 x 0.50 mm WW/WL: 2000/600 HIR: C_SOFT_AA, KARL: 8 CardioBoost: 5

Contrast

Refined Diagnostic Capability

Refined Diagnostic Capability

CardioBoost has lower image noise, and clearer visualization of myocardial and valve structures, which aids in the diagnosis of structural heart disease.

CorCTA Axial

kV: 100 mAs: 106 0.25 s/rotation CTDIvol: 11.67 mGy ED: 2.61 mSv

Reconstruction

Matrix: 512 x 512 Slice: 0.50 x 0.50 mm WW/WL: 800/150 HIR: C_SOFT_AA, KARL: 8 CardioBoost: 1

Contrast

Intelligent Workflow for Cardiac Imaging

The AI-empowered cardiac workflow offers operational efficiencies that make complicated cardiac exams simple and intuitive.

Efficient Positioning

Efficient Positioning

With uAI Vision, uCT 960+ enables precise patient positioning with a single-click for cardiac imaging.

Adaptive Scanning

Adaptive Scanning

CardioAssist: evaluating the patient's heart rate and offering automated gating settings.

CardioAdapt: detecting and skipping irregular heartbeats, thus avoiding rescan.

Motion Correction

Motion Correction

CardioXphase: intelligently selecting the global optimal phase and providing the optimal phase for individual coronary arteries.

CardioCapture: precisely extracting the centerlines of coronary arteries, thus revealing the true vision underneath the blur.

Precise Image Reconstruction

Precise Image Reconstruction

CardioBoost: AI-empowered imaging reconstruction that is specialized in cardiac imaging.

Post-processing*

Post-processing*

uOmnispace: experiencing intelligent post-processing for unparalleled efficacy.

One-stop Combined CCTA Imaging for Panvascular Diseases

uCT 960+ enables a combined acquisition mode of ECG-gated and non-ECG-gated imaging with a rapid switching time of down to 2 seconds. This feature allows uCT 960+ to capture high-quality coronary images, along with cerebrovascular or peripheral vascular CTA images, using just one injection of contrast media.

AI-driven Smart Imaging

uCT 960+ leverages advanced AI to enhance both diagnostic confidence and clinical efficacy. AI-driven capabilities improve image quality by reducing noise and artifacts, providing clear, accurate images for confident decision-making. At the same time, AI streamlines workflows, automating key processes to boost clinical efficiency and reduce operator dependence, ultimately enabling faster and more reliable examination results.

AIIR* – AI Iterative Reconstruction

AIIR* – AI Iterative Reconstruction

As the world's first** combined AI and IR–based reconstruction, AIIR is a pioneering image reconstruction approach that integrates a holistic model-based iterative reconstruction (MBIR) with advanced deep learning technology. Throughout the iterative loop of forward and backward projection between the raw data domain and the image domain, AIIR consistently takes into account the accurate modeling of optics, noise, anatomy, and physics statistics. Additionally, AIIR integrates deep learning-based de-noising technology, supplanting the conventional regularization role of MBIR in the optimization reconstruction process. In brief, AIIR utilizes deep learning-based AI technology to attain robust noise reduction and natural image texture, while incorporating MBIR technology to achieve precise anatomical structure representation and artifact suppression. This technique surpasses the limitations of using either MBIR or deep learning reconstruction (DLR) independently.

Unparalleled Image Quality

Unparalleled Image Quality

With AIIR Technology, image quality is substantially improved through increased spatial resolution and low-contrast detectability (LCD), while maintaining an image texture that radiologists find familiar.

Up to 267%*LCD improvement
Up to 150%*Spatial resolution improvement
Up to 90%*Dose reduction
Up to 98%*Image noise reduction

High Resolution Image

Significantly reduced image noise with a 76% dose reduction*.

Enhances low-contrast detectability for clearer visualization of the right adrenal adenoma.

Suppresses artifacts in the shoulder and pelvis areas.

High Resolution Image

High Resolution Image

Significantly reduced image noise with a 76% dose reduction*.

Enhances low-contrast detectability for clearer visualization of the right adrenal adenoma.

Suppresses artifacts in the shoulder and pelvis areas.

ChestUnionAbd

160×0.5mm 0.5 sec/rotation kV: 80; mAs: 162 CTDIvol: 3.486 mGy Eff. Dose: 3.48 mSv

Recon

Matrix: 512x512 Slice: 1.0x1.0 mm HIR: B_SOFT_B/KARL 5 AIIR: BodyStandard/AIIR 5 WW/WL: 300/40

Contrast

350 mg/ml, 70 ml, 2.5 ml/s

Lower Radiation Dose

Lower Radiation Dose

The AIIR image significantly reduces image noise compared to the HIR image while greatly reducing the radiation dose.

The AIIR image shows enhanced contrast between inflammatory lesions and the lung tissue.

Chest Helical

160×0.5mm 0.5 sec/rotation kV: 80; mAs: 10 CTDIvol: 0.222 mGy Eff. Dose: 0.12 mSv

Recon

Matrix: 512x512 Slice: 1.0x1.0 mm HIR: B_SHARP_C AIIR: LungStandard/AIIR:5

Contrast

-

Consistent Image Quality

Consistent Image Quality

For this patient who couldn't lift his arms, severe streak artifacts appeared in the FBP image.

These artifacts are effectively eliminated in the AIIR image.

ChestUnionAbd

160×0.5mm 0.5 sec/rotation Pitch: 1.37 kV: 120 mAs: 10 CTDIvol: 0.67 mGy Eff. Dose: 1.6 mSv

Recon

Matrix: 512x512 Slice: 0.5x0.5 mm HIR: B_SHARP_C AIIR: LungStandard/AIIR:5 WW/WL: 300/40

Contrast

-

uAI Vision – AI Empowered Scan Workflow

Using a 3D camera, uAI Vision enables single-click, precise, horizontal and isocenter patient positioning, allowing for easy, reproducible, and efficient scanning.

EasyPositioningSingle-click patient positioning with precise scan range planning based on the selected protocol.
EasyISOAutomatically adjusts the table height for high-quality CT images and optimized surface radiation dose distribution.

Organ-Based Auto ALARA mA

Automatically recognizing the regions of the chest and abdomen using AI-based technology, Organ-Based Auto ALARA mA enables dedicated and precise dose modulation for combined chest and abdomen scans. Compared with conventional scan modes, this innovative technology provides accurate dose modulation, consistent image quality and a streamlined clinical workflow.

A: Chest or abdomen helical protocol

An overdose or underdose may occur in the chest or abdomen area when a chest or abdomen protocol is employed to scan the combined region, as only a single set of dose modulation parameters is utilized.

A: Chest or abdomen helical protocol

A: Chest or abdomen helical protocol

An overdose or underdose may occur in the chest or abdomen area when a chest or abdomen protocol is employed to scan the combined region, as only a single set of dose modulation parameters is utilized.

B: Chest helical + abdomen helical protocols

Utilizing separate chest and abdomen protocols for scanning the combined region can increase the radiation dose due to overlapping scans from both protocols.

C: Organ-Based Auto ALARA mA

Organ-Based Auto ALARA mA allows for the implementation of a single protocol combining chest and abdomen scans, achieving equivalent image quality to two separate protocols while reducing radiation dose and scanning time.

Clinical Advantages of Organ-Based Auto ALARA mA

Clinical Advantages of Organ-Based Auto ALARA mA

Based on phantom tests, the image noise in the chest and abdomen are equivalent between the Organ-Based Auto ALARA mA and the individual chest/abdomen protocols. The result of phantom tests reveal that Organ-Based Auto ALARA mA reduces radiation dose by approximately 20% due to precise dose modulation without overlapping scans.

Scan & Reconstruction – EasyRange

The EasyRange technology simplifies the workflow by automatically and precisely determining scan and reconstruction ranges through advanced deep learning techniques. This feature accommodates various routine and specialized scans, such as head, neck, chest, abdomen, spine, extremities, cardiac and combined protocols.

EasyRange for scan

EasyRange for scan

In real-time, it monitors patient movement and determines the starting line and scan range.

EasyRange for reconstruction

EasyRange for reconstruction

After the scout scan, the system will automatically identify the target body part and plan the reconstruction range.

All-rounded Clinical Versatility

uCT 960+ is designed to meet the diverse needs of modern healthcare with its clinical versatility across multiple specialties. Whether it's stroke imaging, oncology, emergency care, or the unique requirements of bariatric and pediatric imaging, uCT 960+ provides reliable and high-quality results. This helps healthcare professionals deliver precise, timely diagnoses, regardless of the clinical scenario, improving overall outcomes and patient care.

Expanded Stroke Imaging Capabilities

16 cm Detector CoverageWith 16 cm z-axis detector coverage, the whole brain can be covered in a single rotation without table movement.
One-stop 4D CTA+CTP ImagingThe one-stop protocol with adjustable radiation dose and cycle time can acquire CTA and CTP information with a single contrast media injection.
Motion FreezeIndustry-first AI-based head motion correction algorithm**, which depicts the truth under motion artifacts
Intelligent Stroke EvaluationAutomatically calculate critical stroke-related metrics, including cerebral blood volume (CBV), cerebral blood flow (CBF), time to peak (TTP), mean transit time (MTT), Tmax, and the mismatch ratio.
Expanded Emergency Imaging Capabilities

Expanded Emergency Imaging Capabilities

Single Rotation Brain ImagingAn entire scan can be completed in half a second to minimize the motion artifacts.
Up to 440 mm/s Fast ScanFast scans for trauma or other emergency patients.
Real Time 3DMPR or VR preview images in real-time during the acquisition.
Intelligent and Precise AnalysisComprehensive and accurate intelligent rib fracture analysis.
Expanded Bariatric Imaging Capabilities

Expanded Bariatric Imaging Capabilities

82 cm Ultra-wide BoreThe expansive 82 cm bore allows for easy scanning of larger patients and provides comfortable experience for patients.
318 kg Table Load CapacityThe large load capacity, combined with an 82 cm bore size, enables efficient scanning for large patients even in challenging situations.
Ultra EFOVAI-empowered algorithm that enables entire bore size imaging, and truncation artifacts suppression.
AIIR Technology*The AI-based de-noising technology offers improved images with superior low-contrast detection and optimal noise texture for bariatric imaging.
Expanded Pediatric Imaging Capabilities

Expanded Pediatric Imaging Capabilities

16 cm Single-rotation ImagingWith a single rotation and up to 16 cm scan range, uCT 960+ can reduce sedation needs for pediatric patients.
Dedicated Pediatric ProtocolsTailored pediatric protocols, based on age and weight, can maximize efficiency and minimize radiation dose for each pediatric patients.
60 kVp Scan ModeThe 60 kVp scan mode significantly reduces radiation dose compared to higher kVp settings, while maintaining image quality.
Expanded Oncology Imaging Capabilities

Expanded Oncology Imaging Capabilities

Dual-Energy ScansEnables the acquisition of 80 kVp and 140 kVp dual-energy for spectral analysis.
16 cm Stationary Perfusion ScansWhole organ perfusion without table movement.
Up to 40 cm Dynamic Perfusion ScansDynamic perfusion scanning in a helical mode with the table moving back and forth for functional analyses.

Customer Voice

Leaving No Patients Behind

Leaving No Patients Behind

Prof. Stefanini – Policlinico Casilino – Rome, Italy "Every week the number of Cardio CT is increased by 10%, and within half a year, the total CT scans been acquired has increased by more than 13%. Most importantly, NONE of the examinations were rejected due to high frequency."

Tailored for Optimal CareDr. Marvin Tamaña – Philippine Heart Center – Manila, Philippine"Managing complex vascular cases requires a multidisciplinary approach, making advanced imaging for precise treatment especially appealing. uCT 960+ has proven instrumental in enhancing the diagnostic accuracy and efficacy. The machine provides rapid image acquisition, 160 mm axial scanning allowing one-heart-beat acquisition with premium image quality and minimal motion artifacts."

Technical Specifications

Gantry bore size82 cm
Gantry tilt±30°
Detectors16 cm Z-axis coverage 0.5 mm x 320 rows with 3D collimator grid
Number of slicesUp to 640 slices/rotation
Rotation timeUp to 0.25 sec/rotation
Temporal resolutionUp to 25 ms with CardioCapture
Table loadUp to 318 kg
kV settings60/70/80/100/120/140 kV
GeneratorUp to 100 kW
Manufacturer notes (9)
  1. *CardioBoost images compared with FBP based on phantom tests. Data on file.
  2. 50 ml, 4.5 ml/s
  3. *Optional **First 510(k) FDA Cleared; CE marked
  4. *AIIR images compared with FBP based on phantom tests. Data on file.
  5. * Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL. U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations.
  6. The product may not be commercially available in all countries. Please check with your local United Imaging Healthcare representative for availability.
  7. This product is intended for use by trained medical professionals only. Patients should follow the guidance and instructions provided by healthcare practitioners during operation.
  8. The supported languages of instruction for use include: English, French, Spanish, et al. Qualified users may access the instruction for use in the appropriate language via the provided link: https://uicloud.com/uclass/docs/en-us/home
  9. Please contact your local United Imaging Healthcare organization for further details.
Computed Tomography

Related devices

View the whole category
Dual-wide Coverage CTUnited Imaging uCT SiriuX Ultrix
United ImagingComputed Tomography

uCT SiriuX Ultrix CT

Profound Acuity. Translating Vitality.

uCT SiriuX Ultrix brings a new level of versatility to CT imaging. Its dual-wide coverage architecture integrates high spatial resolution, fast temporal resolution, extensive volumetric coverage, low-dose imaging, and high-definition spectral imaging within a single platform. From anatomical detail to physiological motion and material composition, it offers a broader view of what CT can reveal.

View details
Dual-wide Coverage CTUnited Imaging uCT SiriuX
United ImagingComputed Tomography

uCT SiriuX CT

Vertices Unite, Innovations Ignite

CT continues to evolve, moving beyond static anatomy to reveal the dynamics of human physiology. With its dual-wide coverage architecture, uCT SiriuX combines ultra-fast temporal resolution, extensive volumetric coverage, and advanced spectral imaging. It enables clinicians to see more, understand more, and capture the dynamics of life.

View details
Premium CTUnited Imaging uCT 868
United ImagingComputed Tomography

uCT 868 CT

From Intelligence to Instinct

The uCT 868 ushers in a new era of high-end CT imaging, seamlessly integrating advanced AI with hardware excellence. By uniting advancements in image perception, motion detection, and workflow optimization, this platform empowers healthcare professionals to see more, achieve more, and operate less.

View details
Premium CTUnited Imaging uCT 820
United ImagingComputed Tomography

uCT 820 CT

Intelligence That Adapts. Clarity That Transcends.

The uCT 820 scanner is equipped with advanced AI technologies and designed with a patient-centered philosophy. It provides comprehensive tissue characterization, minimizes radiation exposure, enables rapid volumetric imaging, and streamlines exam setup for enhanced patient throughput. uCT 820 delivers an exceptional premium CT examination experience for both you and your patients.

View details
Performance CTUnited Imaging uCT 780
United ImagingComputed Tomography

uCT 780 CT

Precision. Accelerated.

As clinical examinations become more complex, the demands on CT scanner performance increase, requiring improvements not only in patient care but also in workflow efficiency. uCT 780, equipped with advanced AI technology, enhances image quality while reducing dose, simplifies the examination process for technicians, and offers versatility for radiologists handling a broad spectrum of clinical scenarios.

View details
Performance CTUnited Imaging uCT 760
United ImagingComputed Tomography

uCT 760 CT

Performance. Profound.

The uCT 760 is a 128-slice CT featuring a fully integrated Z-Detector. The ultra-low electronic noise of the Z-Detector, along with a powerful imaging chain, greatly improves the clinical user experience. The system reveals diagnostic details with minimized radiation dose and provides comprehensive and reliable cardiac imaging capability.

View details
Talk to an expert

Your trusted partner in healthcare.

Tell us what you need. A specialist will call you back within one business day.

We only use your details to answer this request.