Resolution Boost
Spatial Attention Module
Bringing clearer visualization of the targeting area such as plaques and stents.
Up to 72%*
Improvements in spatial resolution with the same radiation dose

Attainable Intelligence. Simply Masterful.
Born with AI, uCT 960+ is an ultra-premium CT scanner equipped with industry-leading AI-empowered technologies. Its AI features give it the capability to deliver unmatched image quality for confident diagnoses with exceptional clinical efficacy. By infusing AI with an elevated hardware platform, uCT 960+ offers precise imaging and ease of use for all types of patients from routine to advanced applications, including cardiac, acute care, trauma, and oncology.
Born with AI, uCT 960+ is an ultra-premium CT scanner equipped with industry-leading AI-empowered technologies. Its AI features give it the capability to deliver unmatched image quality for confident diagnoses with exceptional clinical efficacy. By infusing AI with an elevated hardware platform, uCT 960+ offers precise imaging and ease of use for all types of patients from routine to advanced applications, including cardiac, acute care, trauma, and oncology.
| Manufacturer | United Imaging |
|---|---|
| Category | Computed Tomography |
| Class | Premium CT |
| Installation & training | Included |
| Service coverage | Nationwide, certified engineers |
| Supplied in Iraq by | SAAEDA · official distributor |

Cardiovascular diseases are the most common cause of death globally and Coronary CT Angiography (CCTA) is the examination method that is highly recommended by European Society of Cardiology (ESC), American Heart Association (AHA), and many other institutions. However, since the heart is constantly beating during the examination, cardiac imaging is one of the most challenging scenarios. uCT 960+ equipped with unparallel AI features has now made it simple as breathing. Paired with elevated hardware, 16 cm Z-axis coverage detector and 0.25 sec rotation speed, uCT 960+ can provide seamless examination experience and meanwhile, eliminates the restriction of patients, allowing high heart rate, arrhythmia, and free breathing cardiac imaging.
AI-empowered cardiac imaging reconstruction.

Spatial Attention Module
Bringing clearer visualization of the targeting area such as plaques and stents.
Up to 72%*
Improvements in spatial resolution with the same radiation dose

With spatial attention module, it can reduce blooming artifacts, and therefore allowing a precise evaluation about the degrees of coronary stenosis.
CardioBoost delivers higher resolution of distal vessels and, meanwhile, provides clearer depiction with lower noise of the non-calcified plaques.

CardioBoost delivers higher resolution of distal vessels and, meanwhile, provides clearer depiction with lower noise of the non-calcified plaques.
CorCTA Axial
kV: 100 mAs: 187 0.25 s/rotation CTDIvol: 21.13 mGy ED: 4.73 mSv
Reconstruction
Matrix: 512 x 512 Slice: 0.50 x 0.50 mm WW/WL: 800/150 HIR: C_SOFT_AA, KARL: 8 CardioBoost: 1
Contrast

CardioBoost can reduce image noise and, meanwhile, improve the stent resolution with clear contours.
CorCTA Axial
kV: 120 mAs: 148 0.25 s/rotation CTDIvol: 26.827 mGy ED: 5.26 mSv
Reconstruction
Matrix: 512 x 512 Slice: 0.50 x 0.50 mm WW/WL: 2000/600 HIR: C_SOFT_AA, KARL: 8 CardioBoost: 5
Contrast

CardioBoost has lower image noise, and clearer visualization of myocardial and valve structures, which aids in the diagnosis of structural heart disease.
CorCTA Axial
kV: 100 mAs: 106 0.25 s/rotation CTDIvol: 11.67 mGy ED: 2.61 mSv
Reconstruction
Matrix: 512 x 512 Slice: 0.50 x 0.50 mm WW/WL: 800/150 HIR: C_SOFT_AA, KARL: 8 CardioBoost: 1
Contrast
The AI-empowered cardiac workflow offers operational efficiencies that make complicated cardiac exams simple and intuitive.

With uAI Vision, uCT 960+ enables precise patient positioning with a single-click for cardiac imaging.

CardioAssist: evaluating the patient's heart rate and offering automated gating settings.
CardioAdapt: detecting and skipping irregular heartbeats, thus avoiding rescan.

CardioXphase: intelligently selecting the global optimal phase and providing the optimal phase for individual coronary arteries.
CardioCapture: precisely extracting the centerlines of coronary arteries, thus revealing the true vision underneath the blur.

CardioBoost: AI-empowered imaging reconstruction that is specialized in cardiac imaging.

uOmnispace: experiencing intelligent post-processing for unparalleled efficacy.
uCT 960+ enables a combined acquisition mode of ECG-gated and non-ECG-gated imaging with a rapid switching time of down to 2 seconds. This feature allows uCT 960+ to capture high-quality coronary images, along with cerebrovascular or peripheral vascular CTA images, using just one injection of contrast media.
uCT 960+ leverages advanced AI to enhance both diagnostic confidence and clinical efficacy. AI-driven capabilities improve image quality by reducing noise and artifacts, providing clear, accurate images for confident decision-making. At the same time, AI streamlines workflows, automating key processes to boost clinical efficiency and reduce operator dependence, ultimately enabling faster and more reliable examination results.

As the world's first** combined AI and IR–based reconstruction, AIIR is a pioneering image reconstruction approach that integrates a holistic model-based iterative reconstruction (MBIR) with advanced deep learning technology. Throughout the iterative loop of forward and backward projection between the raw data domain and the image domain, AIIR consistently takes into account the accurate modeling of optics, noise, anatomy, and physics statistics. Additionally, AIIR integrates deep learning-based de-noising technology, supplanting the conventional regularization role of MBIR in the optimization reconstruction process. In brief, AIIR utilizes deep learning-based AI technology to attain robust noise reduction and natural image texture, while incorporating MBIR technology to achieve precise anatomical structure representation and artifact suppression. This technique surpasses the limitations of using either MBIR or deep learning reconstruction (DLR) independently.

With AIIR Technology, image quality is substantially improved through increased spatial resolution and low-contrast detectability (LCD), while maintaining an image texture that radiologists find familiar.
Significantly reduced image noise with a 76% dose reduction*.
Enhances low-contrast detectability for clearer visualization of the right adrenal adenoma.
Suppresses artifacts in the shoulder and pelvis areas.

Significantly reduced image noise with a 76% dose reduction*.
Enhances low-contrast detectability for clearer visualization of the right adrenal adenoma.
Suppresses artifacts in the shoulder and pelvis areas.
ChestUnionAbd
160×0.5mm 0.5 sec/rotation kV: 80; mAs: 162 CTDIvol: 3.486 mGy Eff. Dose: 3.48 mSv
Recon
Matrix: 512x512 Slice: 1.0x1.0 mm HIR: B_SOFT_B/KARL 5 AIIR: BodyStandard/AIIR 5 WW/WL: 300/40
Contrast
350 mg/ml, 70 ml, 2.5 ml/s

The AIIR image significantly reduces image noise compared to the HIR image while greatly reducing the radiation dose.
The AIIR image shows enhanced contrast between inflammatory lesions and the lung tissue.
Chest Helical
160×0.5mm 0.5 sec/rotation kV: 80; mAs: 10 CTDIvol: 0.222 mGy Eff. Dose: 0.12 mSv
Recon
Matrix: 512x512 Slice: 1.0x1.0 mm HIR: B_SHARP_C AIIR: LungStandard/AIIR:5
Contrast
-

For this patient who couldn't lift his arms, severe streak artifacts appeared in the FBP image.
These artifacts are effectively eliminated in the AIIR image.
ChestUnionAbd
160×0.5mm 0.5 sec/rotation Pitch: 1.37 kV: 120 mAs: 10 CTDIvol: 0.67 mGy Eff. Dose: 1.6 mSv
Recon
Matrix: 512x512 Slice: 0.5x0.5 mm HIR: B_SHARP_C AIIR: LungStandard/AIIR:5 WW/WL: 300/40
Contrast
-
Using a 3D camera, uAI Vision enables single-click, precise, horizontal and isocenter patient positioning, allowing for easy, reproducible, and efficient scanning.
Automatically recognizing the regions of the chest and abdomen using AI-based technology, Organ-Based Auto ALARA mA enables dedicated and precise dose modulation for combined chest and abdomen scans. Compared with conventional scan modes, this innovative technology provides accurate dose modulation, consistent image quality and a streamlined clinical workflow.
An overdose or underdose may occur in the chest or abdomen area when a chest or abdomen protocol is employed to scan the combined region, as only a single set of dose modulation parameters is utilized.

An overdose or underdose may occur in the chest or abdomen area when a chest or abdomen protocol is employed to scan the combined region, as only a single set of dose modulation parameters is utilized.
B: Chest helical + abdomen helical protocols
Utilizing separate chest and abdomen protocols for scanning the combined region can increase the radiation dose due to overlapping scans from both protocols.
C: Organ-Based Auto ALARA mA
Organ-Based Auto ALARA mA allows for the implementation of a single protocol combining chest and abdomen scans, achieving equivalent image quality to two separate protocols while reducing radiation dose and scanning time.

Based on phantom tests, the image noise in the chest and abdomen are equivalent between the Organ-Based Auto ALARA mA and the individual chest/abdomen protocols. The result of phantom tests reveal that Organ-Based Auto ALARA mA reduces radiation dose by approximately 20% due to precise dose modulation without overlapping scans.
The EasyRange technology simplifies the workflow by automatically and precisely determining scan and reconstruction ranges through advanced deep learning techniques. This feature accommodates various routine and specialized scans, such as head, neck, chest, abdomen, spine, extremities, cardiac and combined protocols.

In real-time, it monitors patient movement and determines the starting line and scan range.

After the scout scan, the system will automatically identify the target body part and plan the reconstruction range.
uCT 960+ is designed to meet the diverse needs of modern healthcare with its clinical versatility across multiple specialties. Whether it's stroke imaging, oncology, emergency care, or the unique requirements of bariatric and pediatric imaging, uCT 960+ provides reliable and high-quality results. This helps healthcare professionals deliver precise, timely diagnoses, regardless of the clinical scenario, improving overall outcomes and patient care.





Prof. Stefanini – Policlinico Casilino – Rome, Italy "Every week the number of Cardio CT is increased by 10%, and within half a year, the total CT scans been acquired has increased by more than 13%. Most importantly, NONE of the examinations were rejected due to high frequency."
| Gantry bore size | 82 cm |
|---|---|
| Gantry tilt | ±30° |
| Detectors | 16 cm Z-axis coverage 0.5 mm x 320 rows with 3D collimator grid |
| Number of slices | Up to 640 slices/rotation |
| Rotation time | Up to 0.25 sec/rotation |
| Temporal resolution | Up to 25 ms with CardioCapture |
| Table load | Up to 318 kg |
| kV settings | 60/70/80/100/120/140 kV |
| Generator | Up to 100 kW |

Profound Acuity. Translating Vitality.
uCT SiriuX Ultrix brings a new level of versatility to CT imaging. Its dual-wide coverage architecture integrates high spatial resolution, fast temporal resolution, extensive volumetric coverage, low-dose imaging, and high-definition spectral imaging within a single platform. From anatomical detail to physiological motion and material composition, it offers a broader view of what CT can reveal.
View details
Vertices Unite, Innovations Ignite
CT continues to evolve, moving beyond static anatomy to reveal the dynamics of human physiology. With its dual-wide coverage architecture, uCT SiriuX combines ultra-fast temporal resolution, extensive volumetric coverage, and advanced spectral imaging. It enables clinicians to see more, understand more, and capture the dynamics of life.
View details
From Intelligence to Instinct
The uCT 868 ushers in a new era of high-end CT imaging, seamlessly integrating advanced AI with hardware excellence. By uniting advancements in image perception, motion detection, and workflow optimization, this platform empowers healthcare professionals to see more, achieve more, and operate less.
View details
Intelligence That Adapts. Clarity That Transcends.
The uCT 820 scanner is equipped with advanced AI technologies and designed with a patient-centered philosophy. It provides comprehensive tissue characterization, minimizes radiation exposure, enables rapid volumetric imaging, and streamlines exam setup for enhanced patient throughput. uCT 820 delivers an exceptional premium CT examination experience for both you and your patients.
View details
Precision. Accelerated.
As clinical examinations become more complex, the demands on CT scanner performance increase, requiring improvements not only in patient care but also in workflow efficiency. uCT 780, equipped with advanced AI technology, enhances image quality while reducing dose, simplifies the examination process for technicians, and offers versatility for radiologists handling a broad spectrum of clinical scenarios.
View details
Performance. Profound.
The uCT 760 is a 128-slice CT featuring a fully integrated Z-Detector. The ultra-low electronic noise of the Z-Detector, along with a powerful imaging chain, greatly improves the clinical user experience. The system reveals diagnostic details with minimized radiation dose and provides comprehensive and reliable cardiac imaging capability.
View detailsTell us what you need. A specialist will call you back within one business day.