uMammo 870i

No More Anxious Waiting

uMammo 870i is a Contrast-Enhanced Mammography System. It innovatively integrates Contrast-Enhanced Mammography and Contrast-Enhanced Guided Biopsy, enabling the completion of a uCEM exam in only 7 minutes. It eliminates the long waits for appointment scheduling and test results, relieving women of the anxiety associated with breast screening procedures.

Overview

uMammo 870i is a Contrast-Enhanced Mammography System. It innovatively integrates Contrast-Enhanced Mammography and Contrast-Enhanced Guided Biopsy, enabling the completion of a uCEM exam in only 7 minutes. It eliminates the long waits for appointment scheduling and test results, relieving women of the anxiety associated with breast screening procedures.

ManufacturerUnited Imaging
CategoryMammography
Installation & trainingIncluded
Service coverageNationwide, certified engineers
Supplied in Iraq bySAAEDA · official distributor
01Less Waiting
02Natural Fit
03Better Care
Less Waiting

Less Waiting

uMammo 870i innovatively integrates Contrast-Enhanced Mammography and Contrast-Enhanced Guided Biopsy, enabling the completion of a uCEM exam in only 7 minutes. It eliminates the long waits for appointment scheduling and test results, relieving women of the anxiety associated with breast screening procedures.

Contrast-Enhanced Mammography

Contrast-Enhanced Mammography

Efficiency: The CEM examination takes only 7 minutes, eliminating the long wait for MRI scheduling and scanning. Applicability: No MRI equipment compatibility restrictions, can accommodate patients with claustrophobia or metal implants. Accuracy: Effectively improves the ability to differentiate between benign and malignant conditions, reducing repeat examinations and waits caused by missed diagnoses, misdiagnoses, and unnecessary biopsies.

Contrast-Enhanced Guided Biopsy

Contrast-Enhanced Guided Biopsy

Accuracy: Utilizes contrast agent blood flow visualization to accurately target the active area of the lesion (rather than necrotic tissue), avoiding the pain and delays associated with repeat biopsies. Efficiency: The entire process takes only 20-30 minutes, reducing the time compared to MRI-guided biopsy by more than half. Applicability: Suitable not only for precise diagnosis in top hospitals but also easily promotable in private hospitals, securing the golden window for early diagnosis and treatment of breast cancer.

Natural Fit

Natural Fit

United Imaging innovatively adopts 15° and 40° dual-angle tomosynthesis, enabling personalized diagnosis and treatment protocols tailored to different lesion types. And Tomosynthesis Guided Biopsy can be correspondingly performed under both scan modes. This "on-demand switching" design not only meets the efficiency requirements of large-scale screening but also upholds the medical standards for accurate diagnosis, delivering the optimal choice for you.

Innovative Dual-angle DBT

Innovative Dual-angle DBT

15° Fast Scan Mode: better choice for screening; fast speed; low dose; higher in-plane resolution; better visibility and edge clarity of various lesions; diagnostic sensitivity increased by over 10%.

40° HD Scan Mode: better choice for diagnosis; superior 3D resolution; improved imaging quality and detection capability for masses and structural distortions; further enhanced diagnostic efficacy for dense breasts.

Dual-angle uTomo Biopsy

Dual-angle uTomo Biopsy

Faster process: Compared to FFDM-Biopsy, puncture time shortened, entire process only takes about 13 min. Lower dose: Compared to FFDM-Biopsy, radiation dose reduced, one DBT scan can locate the lesion. Precise localization: Small angle for calcification clusters, large angle for masses. Eliminates lesion localization uncertainty.

Better Care

Better Care

uMammo 870i offers a system patient centricity that makes patients comfortable, relaxed and also easy for technologists to operate that aims to increase patient satisfaction.

Intelligent Adaptive Compression

Intelligent Adaptive Compression

uMammo 870i intelligent compression automatically stops compression at the ideal moment and releases the breast immediately after exposure, minimizing manual adjustments and maximizing women's comfort.

One-touch Positioning

One-touch Positioning

Benefit from the intelligent one-touch positioning, technicians no longer need to repeatedly move around to adjust the gantry.

Clinical gallery

Fibroglandular dense breast of 61mm in thicknessMassFibroglandular dense breast of 61mm in thicknessFFDM clearly shows an irregular dense palpable mass shadow in the middle of the left posterior-inferior breast with blurred borders and visible lobules. DBT shows more clearly the glandular hyperplasia with multiple sm…
Heterogeneously dense breast of 57mm in thicknessCalcificationHeterogeneously dense breast of 57mm in thicknessFFDM clearly shows a dense nodular shadow posterior to the posterior aspect of the right nipple, with partially clear borders, visible lobulation and a few punctate calcifications within it. DBT shows more clearly the …
Fibroglandular dense breast of 56mm in thicknessAsymmetryFibroglandular dense breast of 56mm in thicknessFFDM clearly shows a focal asymmetry of high density in the upper outer anterior part of the right breast and in the middle of the ipsilateral outer posterior part, with poorly defined borders. DBT shows more clearly a…
Architectural distortionHeterogeneously dense breast of 51mm in thicknessDBT clearly shows glandular hyperplasia in both breasts, partly nodular-like and partly bulging towards the skin. It also clearly shows architectural distortion in the posterior aspect of the right breast.
uStereo Biopsy to acquire suspicious calcificationsBiopsyuStereo Biopsy to acquire suspicious calcificationsStereo Pair clearly pinpoints the target microcalcification. Post-fire Pair clearly shows the position of the needle. Post-biopsy Pair clearly shows the resected portion of the gland, helping to confirm that the target…

uMammo 870i Technical Details

Contrast-Enhanced Mammography

Enabling the completion of a uCEM exam in only 7 minutes

Dual-angle tomosynthesis

15° narrow-angle for fast screening; 40° wide-angle for further diagnosis

uStereo Biopsy System with uTOMO Biopsy & uCEM Biopsy

uCEM Biopsy: More convenient and cost-effective than MRI Biopsy; uTomo Biopsy: More efficient and low-dose compared with FFDM Biopsy

Design for patient comfort

Breathing light; patient armrest; intelligent opposite position; intelligent adaptive compression

uDose intelligent dose control technology

uDose intelligent algorithm for individuals' breast type; full-panel AEC pre-exposure

uMammo 870i Technical Specifications

Tomosynthesis angular range40° wide angle (+/-20°) and 15° narrow angle (+/-7.5°)
Tube motionContinuous tomosynthesis sweep
Tomosynthesis projections21 low-dose projections (40° ); 15 low-dose projections (15°)
Slice thickness1 mm
Detectora-Si
Pixel size76μm
Source to image receptor distance70 cm

uStereo Biopsy System Technical Details

±15° One-click Stereoscopic Imaging

Auto depth calculation & auto lesion positioning; ±1 mm biopsy target accuracy

Horizontal / Vertical Biopsy Direction

Flexible biopsy in both sitting and lateral positions; supports a variety of needles and hooks; 0.1 mm motor motion accuracy

Multiview with visualized needle guidance

Spatial position assessment between needle and lesion

uStereo Biopsy System Technical Specifications

Biopsy target accuracy±1 mm
Movement rangeX: 60 mm ± 1 mm; Y: 50 mm ± 1 mm; Z: 110 mm ± 1 mm
Biopsy directionHorizontal / Vertical
uTOMO BiopsySupported
uCEM BiopsySupported
Needle Guide12G, 13G*, 14G, 15G*, 16G, 18G, 19G, 20G
Needle Holder MC kitApplicable to Core needle & Localization needle
Needle Holder MRST kit*Applicable to Mammotome revolve ® ST
Needle Holder MST kit*Applicable to Mammotome ® ST
Needle Holder EnCor Kit*Applicable to EnCor
* option