uMammo 890i

Pushing the Boundary of Breast Imaging

uMammo 890i is a Low Dose 3D Mammography System that incorporates advanced technology and state-of-the-art design. It achieves 3D imaging with radiation dose comparable to FFDM, allowing radiologists to visualize breast tissue with enhanced clarity for precise detection of abnormalities. United Imaging's vision is to make breast cancer preventable, treatable, and curable through precise early screening.

Overview

uMammo 890i is a Low Dose 3D Mammography System that incorporates advanced technology and state-of-the-art design. It achieves 3D imaging with radiation dose comparable to FFDM, allowing radiologists to visualize breast tissue with enhanced clarity for precise detection of abnormalities. United Imaging's vision is to make breast cancer preventable, treatable, and curable through precise early screening.

ManufacturerUnited Imaging
CategoryMammography
Installation & trainingIncluded
Service coverageNationwide, certified engineers
Supplied in Iraq bySAAEDA · official distributor
01HD Tomosynthesis with 30% Lower Dose*
02Streamlined Workflow for Precise Diagnosis
03Elevating the Standard of Women's Care
HD Tomosynthesis with 30% Lower Dose*

HD Tomosynthesis with 30% Lower Dose*

uMammo 890i utilizes advanced technology to achieve 3D imaging with radiation dose comparable to FFDM. This breakthrough allows radiologists to visualize breast tissue with enhanced clarity, ensuring precise detection of abnormalities.

10.1 lp/mm HD CMOS Detector

10.1 lp/mm HD CMOS Detector

Thanks to harmonized crystal structure and on-pixel amplification, CMOS detectors leverage a higher spatial resolution which enhancing the visibility of small lesions and also significantly reducing the effect of noise and improve dose efficiency without compromising clarity.

uDose Full-panel AEC

uDose Full-panel AEC

Conventional AEC collects breast density information from limited areas. This can lead to inaccurate estimates due to uneven tissue distribution across the breast and affect subsequent exposure. uDose adopts full-panel pre-exposure to cover the entire glandular area of the breast, providing comprehensive data for accurate and precise dose calculations in a variety of clinical settings.

15/40° Dual-angle Tomosynthesis

15/40° Dual-angle Tomosynthesis

Our 40° wide-angle tomosynthesis captures 21 low-dose image projections in a single scan, improving the detection of subtle or unclear lesions at various depths in the breast. This extensive coverage reduces tissue overlap and provides detailed information crucial for accurate diagnosis. Our 15° tomosynthesis offers a faster, lower-dose screening mode with enhanced visibility for calcifications.

Streamlined Workflow for Precise Diagnosis

Streamlined Workflow for Precise Diagnosis

The demand for radiologists is much higher than expected, creating an urgent need for standardized, efficient methods to ease their workload. The uMammo 890i addresses this with a fast, narrow-angle screening process and an easy-to-use, highly accurate biopsy system, helping to reduce the strain on both radiologists and radiographers.

15° Narrow-angle for Fast Exposure

15° Narrow-angle for Fast Exposure

15° Narrow-angle screening mode can reduce scanning time by 30-40% compared to wide-angle diagnostic modes, from scan to reconstruct to present in ~ 10 sec, obtain narrow-angle DBT image slices and also U-view synthesized 2D images.

Contrast-Enhanced Mammography

Contrast-Enhanced Mammography

Efficiency: The CEM examination takes only 7 minutes, eliminating the long wait for MRI scheduling and scanning. Applicability: No MRI equipment compatibility restrictions, can accommodate patients with claustrophobia or metal implants. Accuracy: Effectively improves the ability to differentiate between benign and malignant conditions, reducing repeat examinations and waits caused by missed diagnoses, misdiagnoses, and unnecessary biopsies.

Snap Diagnostic with AI Assistance *

Snap Diagnostic with AI Assistance *

uMammo, powered by AI, streamlines the entire process from breast gland typing to lesion analysis and AI report generation in just one minute. This boosts efficiency for users and ensures accurate diagnoses, helping to address the challenges of radiologist shortages and maintaining diagnostic consistency in healthcare.

Multiview Visualized Needle Guidance for Accurate Acquisition

Multiview Visualized Needle Guidance for Accurate Acquisition

For targeted lesion, uStereo calculates its spatial coordinates using parallax views from ±15°, enhanced with Multiview visualized needle guidance. Multiview precisely maps the target and simulates the needle pathway, enabling accurate biopsy with a target precision of ±1 mm.

Contrast-Enhanced Guided Biopsy

Contrast-Enhanced Guided Biopsy

Accuracy: Utilizes contrast agent blood flow visualization to accurately target the active area of the lesion (rather than necrotic tissue), avoiding the pain and delays associated with repeat biopsies. Efficiency: The entire process takes only 20-30 minutes, reducing the time compared to MRI-guided biopsy by more than half. Applicability: Suitable not only for precise diagnosis in top hospitals but also easily promotable in private hospitals, securing the golden window for early diagnosis and treatment of breast cancer.

Dual-angle uTomo Biopsy

Dual-angle uTomo Biopsy

Faster process: Compared to FFDM-Biopsy, puncture time shortened, entire process only takes about 13 min. Lower dose: Compared to FFDM-Biopsy, radiation dose reduced, one DBT scan can locate the lesion. Precise localization: Small angle for calcification clusters, large angle for masses. Eliminates lesion localization uncertainty.

Elevating the Standard of Women's Care

Elevating the Standard of Women's Care

uMammo 890i offers a system patient centricity that makes patients comfortable, relaxed and also easy for technologists to operate that aims to increase patient satisfaction.

Intelligent Adaptive Compression

Intelligent Adaptive Compression

uMammo 890i intelligent compression automatically stops compression at the ideal moment and releases the breast immediately after exposure, minimizing manual adjustments and maximizing women's comfort.

One-touch Positioning

One-touch Positioning

Benefit from the intelligent one-touch positioning, technicians no longer need to repeatedly move around to adjust the gantry.

Breathing Light & Curved Armrest

Breathing Light & Curved Armrest

Before compression, the breathing light can guide the patient. As the light on one side illuminates, it indicates which breast side should be compressed to prevent mistakes. During compression, patients can place hand on the curved armrest to prevent tension in the pectoralis major muscle, which could otherwise affect compression.

Clinical gallery

Fibroglandular dense breast of 61mm in thicknessMassFibroglandular dense breast of 61mm in thicknessFFDM clearly shows an irregular dense palpable mass shadow in the middle of the left posterior-inferior breast with blurred borders and visible lobules. DBT shows more clearly the glandular hyperplasia with multiple sm…
Heterogeneously dense breast of 57mm in thicknessCalcificationHeterogeneously dense breast of 57mm in thicknessFFDM clearly shows a dense nodular shadow posterior to the posterior aspect of the right nipple, with partially clear borders, visible lobulation and a few punctate calcifications within it. DBT shows more clearly the …
Fibroglandular dense breast of 56mm in thicknessAsymmetryFibroglandular dense breast of 56mm in thicknessFFDM clearly shows a focal asymmetry of high density in the upper outer anterior part of the right breast and in the middle of the ipsilateral outer posterior part, with poorly defined borders. DBT shows more clearly a…
Architectural distortionHeterogeneously dense breast of 51mm in thicknessDBT clearly shows glandular hyperplasia in both breasts, partly nodular-like and partly bulging towards the skin. It also clearly shows architectural distortion in the posterior aspect of the right breast.
uStereo Biopsy to acquire suspicious calcificationsBiopsyuStereo Biopsy to acquire suspicious calcificationsStereo Pair clearly pinpoints the target microcalcification. Post-fire Pair clearly shows the position of the needle. Post-biopsy Pair clearly shows the resected portion of the gland, helping to confirm that the target…

uMammo 890i Technical Details

CMOS detector for high-resolution image

10.1 lp/mm high spatial resolution

uDose intelligent dose control technology

uDose intelligent algorithm for individuals' breast type; full-panel AEC pre-exposure

Dual-angle tomosynthesis

15° narrow-angle for fast screening; 40° wide-angle for further diagnosis

AI-assisted mammography system

Real-time image quality control; automatic assessment of breast tissue density; rapid localization and analysis of lesions; automatic AI report generation

Design for patient comfort

Breathing light; patient armrest; intelligent opposite position; intelligent adaptive compression

uMammo 890i Technical Specifications

Tomosynthesis angular range40° wide angle (+/-20°) and 15° narrow angle (+/-7.5°)
Tube motionContinuous tomosynthesis sweep
Tomosynthesis projections21 low-dose projections (40° ); 15 low-dose projections (15°)
Slice thickness1 mm
DetectorHigh definition CMOS detector
Spatial resolution10.1 lp /mm
Pixel size49.5μm
Source to image receptor distance70 cm

uStereo Biopsy System Technical Details

±15° One-click Stereoscopic Imaging

Auto depth calculation & auto lesion positioning; ±1 mm biopsy target accuracy

Horizontal / Vertical Biopsy Direction

Flexible biopsy in both sitting and lateral positions; supports a variety of needles and hooks; 0.1 mm motor motion accuracy

Multiview with visualized needle guidance

Spatial position assessment between needle and lesion

uStereo Biopsy System Technical Specifications

Biopsy target accuracy±1 mm
Movement rangeX: 60 mm ± 1 mm; Y: 50 mm ± 1 mm; Z: 110 mm ± 1 mm
Biopsy directionHorizontal / Vertical
Needle Guide12G, 13G*, 14G, 15G*, 16G, 18G, 19G, 20G
Needle Holder MC kitApplicable to Core needle & Localization needle
Needle Holder MRST kit*Applicable to Mammotome revolve ® ST
Needle Holder MST kit*Applicable to Mammotome ® ST
Needle Holder EnCor Kit*Applicable to EnCor
* option
Manufacturer notes (2)
  1. * Tested under same circumstances using 40 mm PMMA or real breast of 40-50 mm.