Skip to content
Computed TomographyCT for Routine Exams

uCT Orion Elite

Intelligent Scans, Elevated Insights

The uCT Orion Elite's intelligent workflow enhances scanning and diagnostic efficiency for technologists while delivering comprehensive patient-centered care. With advanced hardware that meets a wide range of clinical needs, even challenging scans are performed with ease, and AI integration elevates image quality to a new standard, giving radiologists greater diagnostic confidence. Designed for operational efficiency, the uCT Orion Elite helps lower daily costs while delivering lasting value.

163%*
74%*
80%*
98%*

Overview

The uCT Orion Elite's intelligent workflow enhances scanning and diagnostic efficiency for technologists while delivering comprehensive patient-centered care. With advanced hardware that meets a wide range of clinical needs, even challenging scans are performed with ease, and AI integration elevates image quality to a new standard, giving radiologists greater diagnostic confidence. Designed for operational efficiency, the uCT Orion Elite helps lower daily costs while delivering lasting value.

ManufacturerUnited Imaging
CategoryComputed Tomography
ClassCT for Routine Exams
Installation & trainingIncluded
Service coverageNationwide, certified engineers
Supplied in Iraq bySAAEDA · official distributor
01Intelligent Workflow for Everyone
02Unlocking Clinical Potential for Expanded Applications
03AI-Driven Imaging for Advanced Clinical Insight
04Smart System Design for Optimized Operations
Intelligent Workflow for Everyone

Intelligent Workflow for Everyone

An intelligent scanning workflow brings benefits to both operators and patients. For operators, they can utilize technologies such as automatic positioning and parameter adjustment to perform scans efficiently and easily. For patients, the uCT Orion Elite employs AI to proactively detect potential imaging problems during scanning, delivering comprehensive care.

Efficiency-Driven Intelligent Scanning

Efficiency-Driven Intelligent Scanning

Easy PositioningBased on 21 anatomical landmark detections, uAI Vision enables automatic identify the appropriate scan position based on the selected protocol. The technologist only needs a single click to position the patient.
Easy Scan PlanninguCT Orion Elite leverages deep learning to streamline workflow. Before the scan begins, it continuously monitors patient movement in real time to appropriately identify the starting line and scan range.
Easy Dose ControluCT Orion Elite optimizes dose according to patient size, scan region, and exam type, recommending the appropriate kV and automatically modulating mA. AI-based organ recognition further enables individualized dose control for chest–abdomen scans.
Easy Post-processinguCT Orion Elite offers a comprehensive suite of console-integrated post-processing applications that streamline workflow by automating repetitive steps and enhancing efficiency across clinical scenarios.
Enhanced Monitoring of Patient Scan Status

Enhanced Monitoring of Patient Scan Status

The uCT Orion Elite's uAI Vision features two cameras, enabling real-time patient monitoring from two distinct views: top-down and close-up. It continuously monitors the patient's status throughout the scan, helping technologists quickly identify issues.

Patient-gantry Collision Check

Patient-gantry Collision Check

The system uses uAI Vision to proactively identify areas at risk of patient-gantry collisions. Once the risk of a patient-gantry collision is detected, the system promptly signals the technologist before table movement, thereby reducing the likelihood of collisions between the patient and the gantry.

AI-based Brain Hemorrhage Detection*

AI-based Brain Hemorrhage Detection*

This algorithm is designed for intracerebral hemorrhage (ICH) detection. It provides technologists with real-time reminders when potential ICH is detected, enabling clinicians to maintain heightened vigilance and preserve valuable time for patient assessment.

Intelligent Imaging with Quality check

To achieve a high scanning success rate and reduce the likelihood of patients being recalled for re - examination, uCT Orion Elite employs AI algorithms to provide real - time prompts during scanning. These prompts notify technologists of factors that may impact image quality, assist them in identifying possible scanning issues, and reduce the likelihood of patient recalls.

Quality Check for Chest

Quality Check for Chest

During chest scans, the AI-empowered quality check monitors the patient's breath-hold status. If the patient fails to hold the breath as required, the system triggers real-time prompts, which helps technologists efficiently confirm chest image quality and reduce patient recalls.

Quality Check for Motion

Quality Check for Motion

Based on AI technology, the uAI Vision in-bore detects patient movement. Once patient's motion is detected, it triggers real - time prompts, enabling technologists to stay vigilant about the patient's scanning status.

Quality Check for Metal

Quality Check for Metal

It automatically detects non-iatrogenic metal (such as belts, keys, necklaces, etc.) and accurately pinpoints their locations in the scout image. This can remind technologists to remove the metal objects, avoiding the generation of artifacts and enhancing image quality.

Unlocking Clinical Potential for Expanded Applications

Unlocking Clinical Potential for Expanded Applications

Robust and reliable hardware supports the uCT Orion Elite across diverse clinical applications. Its stable system makes routine scans efficient and smooth while handling complex scenarios with ease. With powerful performance, it meets the demands of varied clinical applications, delivering exceptional value beyond expectations.

Handle Routine Scans with EaseThe high-performance hardware provides robust support for routine scanning. Utilizing the 80 slices Z-Detector's 0.55mm slice thickness and high sampling rate, the system produces high-quality images with sharp detail visualization. The advanced tube cooling design is well-suited for high-throughput scanning.
Turn challenging into routineHigh tube heat dissipation enables the tube to sustain prolonged exposure during large-range scans, preventing interruptions from heat accumulation. With a maximum tube input power of 48 kW, the system delivers high-quality imaging even in demanding clinical scenarios, such as examinations of obese patients.
Release more clinical potentialuCT Orion Elite unlocks greater clinical potential. It supports ECG-gated coronary artery calcium score * for early heart disease assessment and enables dual-energy scanning* for visualization and compositional analysis of gout tophi. In addition, it offers four scan modes for interventional* imaging.

Clinical gallery

Head & Neck CTA ImagesHead & NeckHead & Neck CTA ImagesScan Parameter: 0.71 sec/rotation kV: 100 mAs: 176 Scan length: 360 mm CTDIvol: 9.1 mGy Eff. Dose: 0.7 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 0.5 mm HIR: H_SOFT+ DL-Denoise: 3 WW/WL: 300/45 Contrast: 350 m…
Low Dose Chest Scan ImagesChestLow Dose Chest Scan ImagesScan Parameter: 0.71 sec/rotation kV: 60 mAs: 140 Scan length: 282 mm CTDIvol: 1.067 mGy Eff. Dose: 0.46 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: B_SHARP+ DL-Denoise: 3 WW/WL: 400/40 Contrast: --
70kV Pulmonary CTA ImagesChest70kV Pulmonary CTA ImagesScan Parameter: 0.71 sec/rotation kV: 70 mAs: 214 Scan length: 298 mm CTDIvol: 3.2 mGy Eff. Dose: 1.43 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 0.5 mm HIR: B_SOFT DL-Denoise: 3 WW/WL: 400/40 Contrast: 350 mg…
Cardiac Calcium Scoring ImagesHeartCardiac Calcium Scoring ImagesScan Parameter: 0.71 sec/rotation kV: 120 mAs: 30 Scan length: 150 mm CTDIvol: 3.718 mGy Eff. Dose: 0.79 mSv Recon Parameter: Matrix: 512 × 512 Slice: 2.2 × 2.2 mm HIR: C_SOFT_B WW/WL: 600/60 Contrast: --
Chest–Abdomen Combined Scan ImagesAbdomenChest–Abdomen Combined Scan ImagesScan Parameter: 0.71 sec/rotation kV: 120 mAs: 94 Scan length: 636 mm CTDIvol: 8.2 mGy Eff. Dose: 7.6 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 0.5 mm HIR: B_SOFT, B_SHARP+ DL-Denoise: 3 WW/WL: 1400/-400, 300…
Abdominal Contrast-Enhanced ImagesAbdomenAbdominal Contrast-Enhanced ImagesScan Parameter: 0.71 sec/rotation kV: 100 mAs: 154 Scan length: 479 mm CTDIvol: 8.0 mGy Eff. Dose: 6.0 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: B_SOFT DL-Denoise: 3 WW/WL: 300/40 Contrast: 350 mg…
Intervention ImagesInterventionIntervention ImagesScan Parameter: Scan Mode: Single Axial kV: 120 mAs: 29 CTDIvol: 13.47 mGy Eff. Dose: 0.187 mSv Recon Parameter: Matrix: 512 × 512 Slice: 2.75 × 2.75 mm HIR: B_SHARP_C WW/WL: 2026/56 Contrast: --
Lower Extremity CTA ImagesLower ExtremityLower Extremity CTA ImagesScan Parameter: 0.71 sec/rotation kV: 100 mAs: 94 Scan length: 1165 mm CTDIvol: 4.9 mGy Eff. Dose: 8.7 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 0.5 mm HIR: B_SOFT DL-Denoise: 3 WW/WL: 300/45 Contrast: 350 mg…
Dual-Energy Ankle ImagesLower ExtremityDual-Energy Ankle ImagesScan Parameter: 0.71 sec/rotation kV: 140&80 mAs: 40&156 Scan length: 210 mm CTDIvol: 9.0 mGy Eff. Dose: 3.2 mSv Recon Parameter: Matrix: 512 × 512 Slice: 1.0 × 1.0 mm HIR: B_SOFT_B&B_SHARP_AA WW/WL: 2600/800, 300/45 C…
AI-Driven Imaging for Advanced Clinical Insight

AI-Driven Imaging for Advanced Clinical Insight

Driven by cutting-edge deep learning, AI is pushing the boundaries of CT imaging by enhancing resolution, improving contrast, and reducing artifacts. These breakthroughs enable clinicians to reveal subtle structures, broaden diagnostic insights, and make more confident decisions to improve patient outcomes.

DELTA* elevates image quality across all dimensions

DELTA* elevates image quality across all dimensions

DELTA(Deep Learning Trained Algorithm) attains a balance among high image quality, low radiation dose, and fast reconstruction speed - a balance that has long been deemed challenging to achieve. With this achievement, DELTA sets a new benchmark in CT imaging.

163%*Up to 163% LCD improvement at the same dose.
74%*Up to 74% spatial resolution improvement at the same dose.
80%*Up to 80% radiation dose reduction at the same low contrast detectability (LCD).
98%*Up to 98% image noise reduction at the same dose.
DELTA Reduces Image Noise and Enhances Low Contrast Detectability

DELTA Reduces Image Noise and Enhances Low Contrast Detectability

Scan Parameter

kV: 120 mAs: 190 CTDIvol: 30.6 mGy Eff. Dose: 1.12 mSv

Recon Parameter

Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: H_SOFT_B DL-Denoise level: 3 WW/WL: 80/40

Contrast

—

DELTA Improves Lung Texture Visualization in Low-Dose Scans

DELTA Improves Lung Texture Visualization in Low-Dose Scans

Scan Parameter

kV: 120 mAs: 10 Scan length: 277mm CTDIvol: 0.9 mGy Eff. Dose: 0.4 mSv

Recon Parameter

Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: B_SOFT_B DL-Denoise level: 3 WW/WL: 1400/-400

Contrast

—

DELTA Reduces Image Noise and Enhances Low Contrast Detectability

DELTA Reduces Image Noise and Enhances Low Contrast Detectability

Scan Parameter

kV: 120 mAs: 101 CTDIvol: 8.8 mGy Eff. Dose: 6.3 mSv

Recon Parameter

Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: B_VSOFT_B DL-Denoise level: 3 WW/WL: 300/400

Contrast

—

DELTA Improves Visualization of Pulmonary Vessels

DELTA Improves Visualization of Pulmonary Vessels

Scan Parameter

kV: 120 mAs: 70 Scan length: 249 mm CTDIvol: 6.1 mGy Eff. Dose: 2.4 mSv

Recon Parameter

Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: B_VSOFT_B DL-Denoise level: 3 WW/WL: 300/40

Contrast

350 mgI/ml 60 ml 4.6ml/s

DELTA Reduces Dose without Compromising Image Quality

DELTA Reduces Dose without Compromising Image Quality

Scan Parameter

kV: 100 mAs: 90 Scan length: 581 mm CTDIvol: 4.7 mGy Eff. Dose: 4.2 mSv

Recon Parameter

Matrix: 512 × 512 Slice: 1.0 × 0.8 mm HIR: B_VSOFT_B DL-Denoise level: 3 WW/WL: 300/40

Contrast

350 mgI/ml 70 ml 3.0 ml/s

DELTA Optimizes CT Imaging for Patients with High BMI

DELTA Optimizes CT Imaging for Patients with High BMI

Patient BMI

31.2

Scan Parameter

kV: 120 mAs: 121 Scan length: 618 mm CTDIvol: 10.6 mGy Eff. Dose: 9.5 mSv

Recon Parameter

Matrix: 512 × 512 Slice: 1.0 × 0.5 mm HIR: B_VSOFT_B DL-Denoise level: 3 WW/WL: 300/40

Contrast

—

3D modeling of the motion pattern to restore the real clinical situation

3D modeling of the motion pattern to restore the real clinical situation

Patient head movement typically involves multiple motion patterns, and no current algorithm can effectively eliminate the resulting artifacts. To establish a gold-standard dataset, the Motion Freeze algorithm simulates artifacts in the X, Y, and Z directions, including rotation, translation, oscillation, and mixed scenarios. By introducing diverse motion artifacts, this approach enables the trained network model to handle a broad spectrum of motion conditions.

Head motion artifacts suppression

Head motion artifacts suppression

Motion Freeze effectively suppresses head motion artifacts, providing a clear view of brain structures without obscuring lesions. By minimizing the need for repeated scans, it saves time, conserves resources, and avoids unnecessary radiation exposure for patients.

Smart System Design for Optimized Operations

Smart System Design for Optimized Operations

The uCT Orion Elite enables optimized operations through smart system design. Its uEco Mode features energy-saving technology that reduces electricity consumption while lowering daily operating costs. When users encounter issues during scanning, remote support is available to assist them, maintaining efficient and stable operation. Leveraging these designs, the uCT Orion Elite improves operational efficiency, delivering greater value to hospitals.

Save More with uEco Mode

Save More with uEco Mode

During idle scanning, such as at night or on weekends, the user can enter uECO mode with one click. The uECO mode effectively reduces power consumption by partially powering down hardware components while maintaining essential functionality to ensure optimal system performance. In uECO mode, the detector remains fully operational, ensuring that its internal components are in an active and stable state. This allows the machine to quickly reach the scanning state when resumed from uECO mode, thus maintaining high-quality image quality.

Remote Service Keeps the System Running Smoothly

The uCT Orion Elite offers Remote-related functionalities. When unexpected issues arise, users can instantly connect with service engineers for timely support. Users can also perform remote software updates, keeping the system performance optimized, enhancing operational efficiency, and unlocking the full potential of the CT.

Technical Details

Tube anode storage capacity3.8 MHU
DetectorZ-Detector
Number of detector rows40
Max. slices generated per rotation80
Range of tube current10~400 mA
Range of tube voltage60~140kV
Generator power48 kW
Aperture70 cm
Table load250 kg
Manufacturer notes (6)
  1. *Registered by United Imaging Intelligence
  2. *Optional*DELTA images compared with FBP based on phantom tests. Data on file.
  3. The product may not be commercially available in all countries. Please check with your local United Imaging Healthcare representative for availability.
  4. This product is intended for use by trained medical professionals only. Patients should follow the guidance and instructions provided by healthcare practitioners during operation.
  5. The supported languages of instruction for use include: English, Russian, Spanish, Italian, Polish, German, Greek, Romanian, Hungarian, and Brazilian Portuguese, et al. Qualified users may access the instruction for use in the appropriate language via the provided link: https://uicloud.com/uclass/docs/en-us/home
  6. Please contact your local United Imaging Healthcare organization for further details.
Computed Tomography

Related devices

View the whole category
Dual-wide Coverage CTUnited Imaging uCT SiriuX Ultrix
United ImagingComputed Tomography

uCT SiriuX Ultrix CT

Profound Acuity. Translating Vitality.

uCT SiriuX Ultrix brings a new level of versatility to CT imaging. Its dual-wide coverage architecture integrates high spatial resolution, fast temporal resolution, extensive volumetric coverage, low-dose imaging, and high-definition spectral imaging within a single platform. From anatomical detail to physiological motion and material composition, it offers a broader view of what CT can reveal.

View details
Dual-wide Coverage CTUnited Imaging uCT SiriuX
United ImagingComputed Tomography

uCT SiriuX CT

Vertices Unite, Innovations Ignite

CT continues to evolve, moving beyond static anatomy to reveal the dynamics of human physiology. With its dual-wide coverage architecture, uCT SiriuX combines ultra-fast temporal resolution, extensive volumetric coverage, and advanced spectral imaging. It enables clinicians to see more, understand more, and capture the dynamics of life.

View details
Premium CTUnited Imaging uCT 960+
United ImagingComputed Tomography

uCT 960+ CT

Attainable Intelligence. Simply Masterful.

Born with AI, uCT 960+ is an ultra-premium CT scanner equipped with industry-leading AI-empowered technologies. Its AI features give it the capability to deliver unmatched image quality for confident diagnoses with exceptional clinical efficacy. By infusing AI with an elevated hardware platform, uCT 960+ offers precise imaging and ease of use for all types of patients from routine to advanced applications, including cardiac, acute care, trauma, and oncology.

View details
Premium CTUnited Imaging uCT 868
United ImagingComputed Tomography

uCT 868 CT

From Intelligence to Instinct

The uCT 868 ushers in a new era of high-end CT imaging, seamlessly integrating advanced AI with hardware excellence. By uniting advancements in image perception, motion detection, and workflow optimization, this platform empowers healthcare professionals to see more, achieve more, and operate less.

View details
Premium CTUnited Imaging uCT 820
United ImagingComputed Tomography

uCT 820 CT

Intelligence That Adapts. Clarity That Transcends.

The uCT 820 scanner is equipped with advanced AI technologies and designed with a patient-centered philosophy. It provides comprehensive tissue characterization, minimizes radiation exposure, enables rapid volumetric imaging, and streamlines exam setup for enhanced patient throughput. uCT 820 delivers an exceptional premium CT examination experience for both you and your patients.

View details
Performance CTUnited Imaging uCT 780
United ImagingComputed Tomography

uCT 780 CT

Precision. Accelerated.

As clinical examinations become more complex, the demands on CT scanner performance increase, requiring improvements not only in patient care but also in workflow efficiency. uCT 780, equipped with advanced AI technology, enhances image quality while reducing dose, simplifies the examination process for technicians, and offers versatility for radiologists handling a broad spectrum of clinical scenarios.

View details
Talk to an expert

Your trusted partner in healthcare.

Tell us what you need. A specialist will call you back within one business day.

We only use your details to answer this request.